Osmotic pump with potential for bone lengthening distracts continuously in vitro and in vivo

Author:

Lippross Sebastian,Lorenz Heiko M.,Braunschweig Lena,Heede Andreas,Büscher Robin,Siegel Marlon,Schultheiß Gerhard,Vieten Sarah,Lüthje Annette,Matzen Andrea,Lüders Katja A.,Jäckle Katharina,Tsaknakis Konstantinos,Hell Anna K.ORCID

Abstract

Background In pediatric orthopedics, long bone lengthening procedures are routinely performed using manual, motorized or magnetically controlled implants. This study aims to prove expansion of a newly designed osmotic pump prior to long bone lengthening in living organisms and to rule out any complications related to in vivo conditions, such as congestion of the semipermeable membrane, local infection, or lack of water to drive the osmotic pump, as well as to compare in vivo and in vitro expansion data. Methods Osmotic pumps, which were designed to distract a plate osteosynthesis, were inserted in the dorsal paraspinal musculature of four piglets. To compare the performance of the pumps in in vivo and in vitro conditions, another set of pumps was submerged in physiologic saline solution at different temperatures. The lengthening progress was measured radiographically and sonographically in the study animals. Results Both, in vitro and in vivo tested osmotic pumps started distraction after an intended rest phase of four days and distracted evenly over the following twelve days. No complications, clogging or damages occurred. However, we observed a temperature dependency of the distraction rate ranging from 0.98 mm/day at 39°C to 1.10 mm/day at 42°C. With a second setup, we confirmed that the distraction rate differed by 72% within a measured temperature interval of 14° C. Conclusions The data presented here confirm that the novel osmotic pump showed comparable lengthening characteristics in vivo and in vitro. No complications, such as congestion of the semipermeable membrane, local infection, or lack of water to drive the osmotic pump were observed. Thus, osmotic pumps may have great potential in future applications such as long bone lengthening procedures, where continuous distraction probably provides a better bone quality than intermittent lengthening procedures. The fact that one pump failed to elongate in each condition, highlights the importance of technical improvement, but also demonstrates that this was not due to different circumstances within the in vivo or in vitro condition.

Funder

Bundesministerium für Bildung und Forschung

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference21 articles.

1. Limb lengthening history, evolution, complications and current concepts;GA Hosny;J Orthop Traumatol,2020

2. The tension-stress effect on the genesis and growth of tissues: Part II. The influence of the rate and frequency of distraction;GA Ilizarov;Clin Orthop Relat Res,1989

3. PRECICE intramedullary limb lengthening system;D. Paley;Expert Rev Med Devices,2015

4. Complications in leg lengthening using an Ilizarov external fixator and intramedullary alignment in children: comparative study during a fourteen-year period;B Bukva;Injury. November,2015

5. Ilizarov technique. Results and difficulties;E García-Cimbrelo;Clin Orthop Relat Res,1992

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. What’s new in pediatric lower limb reconstruction?;Journal of Children's Orthopaedics;2024-06-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3