Echogenic intracardiac foci detection and location in the second-trimester ultrasound and association with fetal outcomes: A systematic literature review

Author:

Jones Hope EleriORCID,Battaglia Serica,Hurt Lisa,Uzun Orhan,Brophy SineadORCID

Abstract

Background Echogenic Intracardiac Foci (EIF) are non-structural markers identified during the routine 18–20-week foetal anomaly ultrasound scan yet their clinical significance on future outcomes for the infant is unclear. Objective To examine the association between EIF and risk of preterm birth, chromosomal abnormalities, and cardiac abnormalities. Design A review across four databases to identify English language journal articles of EIF using a cohort study design. All studies were reviewed for quality using the Critical Appraisal Skills Programme (CASP) checklist and data extracted for comparison and analysis. Results 19 papers from 9 different countries were included. Combining these studies showed 4.6% (95% CI = 4.55–4.65%) of all pregnancies had EIF which was on the left in 86% of cases, on the right in 3% of cases and bilaterally in 10%. There was no evidence that EIF was associated with higher rates of preterm birth. However, it is possible that infants with EIF were more likely to be terminated rather than be born preterm as there was a 2.1% (range 0.3–4.2%) rate of termination or death of the foetus after week 20 among those with EIF. There was no evidence that EIF alone is highly predictive of chromosomal abnormalities. There was evidence that EIF is associated with higher rates of minor cardiac abnormalities (e.g. ventricular septal defect, tricuspid regurgitation or mitral regurgitation)) with 5.1% (224 of 4385) of those with EIF showing cardiac abnormalities (3.08% in retrospective studies and 17.85% in prospective studies). However, the risk of cardiac defects was only higher with right-sided EIF and where the EIF persisted into the third trimester. However, this is a rare event and would be seen in an estimated 4 per 10,000 pregnancies. Conclusion EIF alone was not associated with adverse outcomes for the infant. Only persistent EIF on the right side showed evidence of carrying a higher risk of cardiac abnormality and would warrant further follow-up.

Publisher

Public Library of Science (PLoS)

Reference53 articles.

1. Abnormal findings in fetal echocardiography and maternal disease: A cross-sectional study.;MR Alipour;Int J Reprod Biomed,2022

2. HQIP. Health Quality Improvement Partnership [Internet]. [cited 2023 Dec 21]. Available from: https://www.hqip.org.uk/

3. Referral indications for foetal echocardiography in a low resource setting.;A Ladak;J Pak Med Assoc.,2021

4. Global, regional, and national time trends in mortality for congenital heart disease, 1990–2019: An age-period-cohort analysis for the Global Burden of Disease 2019 study.;Z Su;EClinicalMedicine,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3