Efficiency of octenidine dihydrochloride alcohol combination compared to ethanol based skin antiseptics for preoperative skin preparation in dogs

Author:

Eigner FabianORCID,Keller Stefanie,Schmitt Sarah,Corti Sabrina,Nolff Mirja C.

Abstract

Objective To quantify the bacterial burden after skin disinfection using an alcohol octenidine dihydrochloride combination (Octenisept®) compared to an 74.1% ethanol 10% 2-propanol combination (Softasept N®). Study design Prospective randomized clinical trial. Material & methods 61 dogs undergoing clean or clean-contaminated surgeries (excluding surgeries on the gastrointestinal tract) were randomly assigned to group O (skin disinfection with alcohol and octenidine dihydrochloride after washing with octenidine containing soap) or to control group C (skin disinfection using the ethanol-2-propanol combination after washing with a neutral soap without antiseptic ingredients). Samples were then taken from 8 different locations within the surgical field at four different stages: after clipping, after washing, after disinfection and one hour later. At each stage, two different sampling techniques (wet-dry swab technique (WDS) and contact plates (CP)) were used for quantitative analysis of bacterial counts. Results WDS detected about 100-fold more bacteria compared to CP sampling in cases with high bacterial burden, but was not accurate enough to detect small numbers. CP sampling was therefore used for comparison of treatment protocols. 30 dogs were assigned to group O and 31 to group C. A relative reduction of 69% in group O and 77 percent in group C was observed after the soap wash. No significant differences were detected between both groups. Washing and disinfection resulted in a reduction of bacterial counts of 99.99% in group O versus 99.7% in group C (p = 0.018). Bacterial reduction one hour after washing and disinfection was significantly higher in group O (99.9%) than in group C (98.5%, p = 0.001). Conclusion Additional octenidine dihydrochloride provided a slightly better decontamination effect after disinfection, particularly one hour after, which means it may only be indicated in longer surgeries. WDS is more sensitive but less specific to detect bacteria on the skin than the CP sampling.

Funder

Legat Bachofner, University of Zurich

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3