Clinical usability of 3D gradient-echo-based ultrashort echo time imaging: Is it enough to facilitate diagnostic decision in real-world practice?

Author:

Bak So Hyeon,Park Jinil,Lee Seokwon,Kim Jong HeeORCID,Lee Ho YunORCID,Park Jang-Yeon

Abstract

Background With recent advances in magnetic resonance imaging (MRI) technology, the practical role of lung MRI is expanding despite the inherent challenges of the thorax. The purpose of our study was to evaluate the current status of the concurrent dephasing and excitation (CODE) ultrashort echo-time sequence and the T1-weighted volumetric interpolated breath-hold examination (VIBE) sequence in the evaluation of thoracic disease by comparing it with the gold standard computed tomography (CT). Methods Twenty-four patients with lung cancer and mediastinal masses underwent both CT and MRI including T1-weighted VIBE and CODE. For CODE images, data were acquired in free breathing and end-expiratory images were reconstructed using retrospective respiratory gating. All images were evaluated through qualitative and quantitative approaches regarding various anatomical structures and lesions (nodule, mediastinal mass, emphysema, reticulation, honeycombing, bronchiectasis, pleural plaque and lymphadenopathy) inside the thorax in terms of diagnostic performance in making specific decisions. Results Depiction of the lung parenchyma, mediastinal and pleural lesion was not significant different among the three modalities (p > 0.05). Intra-tumoral and peritumoral features of lung nodules were not significant different in the CT, VIBE or CODE images (p > 0.05). However, VIBE and CODE had significantly lower image quality and poorer depiction of airway, great vessels, and emphysema compared to CT (p < 0.05). Image quality of central airways and depiction of bronchi were significantly better in CODE than in VIBE (p < 0.001 and p = 0.005). In contrast, the depiction of the vasculature was better for VIBE than CODE images (p = 0.003). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significant greater in VIBE than CODE except for SNRlung and SNRnodule (p < 0.05). Conclusions Our study showed the potential of CODE and VIBE sequences in the evaluation of localized thoracic abnormalities including solid pulmonary nodules.

Funder

Ministry of Science and ICT, South Korea

Publisher

Public Library of Science (PLoS)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3