Comparative analysis between different volumetric methods on measuring intracranial hemorrhage incorporating roundness index

Author:

Chaidee SupanutORCID,Inkeaw PapangkornORCID,Makee Thampaphon,Khamyod Kamoltip,Angkurawaranon Salita,Traisathit Patrinee,Vaniyapong Tanat,Chitapanarux ImjaiORCID

Abstract

Intracranial hematoma (ICH) volume is considered a predictor of clinical outcome and mortality rate in ICH patients with traumatic brain injury (TBI). The ABC/2 method for ICH volume is the standard method used to date, however, its level of accuracy has been questioned in some studies. This study compared the performance of the ABC/2 method with planimetry and truncated pyramidal methods to highlight the potential of the planimetry method applied with automatic segmentation for evaluation of epidural hematoma (EDH) and intraparenchymal hematoma (IPH) volume. Six different phantoms were designed to evaluate the accuracy of volume estimation methods. 221 hematoma regions extracted from CT scans of 125 patients with head injury were also used to analyze the efficiency. The roundness index was utilized for the quantification of the ellipsoid-like shape. Regions of EDH and IPH on the CT scans were annotated by radiologists. The estimation errors for each method were statistically analyzed and compared. In addition, the relationship between the errors and roundness index was examined. The planimetry method showed the lowest relative error on phantom data. In the case of the CT scan data, the truncated pyramidal method resulted in the underestimation of the volumes of EDH and IPH. Meanwhile, the ABC/2, through principal component analysis (PCA) in the two-dimensional and PCA in the three-dimensional methods, resulted in a significant overestimation. In addition, both these approaches produced relative errors that showed a correlation with the roundness indexes for IPH. In comparison to other methods, the planimetry method had the lowest level of error with regards to calculation of the volume and it was also independent of the hematoma shape. The planimetry method, therefore, has the potential to serve as a useful tool for the assessment of ICH volume in TBI patients by using a deep learning system.

Funder

Office of National Higher Education Science Research and Innovation Policy Council

Chiang Mai University, Thailand

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3