Abstract
Background
Variable fibrinogen content within cryoprecipitate makes accurate dosing challenging in patients with coagulopathic bleeding, in addition to pathogen transmission risks associated with its administration. Purified and standardized human fibrinogen concentrates (HFCs) represent reliable alternatives. Full cryoprecipitate characterization is required to inform selection of an appropriate fibrinogen source for supplementation therapy.
Methods
Extended biochemical comparison of pooled cryoprecipitate and HFC (Fibryga, Octapharma) was performed using commercially available assays to determine levels of variability in cryoprecipitate and HFC. In addition to standard procoagulant factors, measurements included activities of platelet-derived microparticles (PMPs) and plasminogen, and levels of fibrin degradation products.
Results
Cryoprecipitate contains lower fibrinogen levels than HFC (4.83 vs.19.73 g/L; p<0.001), translating to approximately half the amount of fibrinogen per standard cryoprecipitate dose (two pools, pre-pooled from five donations each) vs. HFC (2.14 vs. 3.95 g; p<0.001). Factor XIII (FXIII) levels were also lower in cryoprecipitate vs. HFC (192.17 vs. 328.33 IU/dL; p = 0.002). Levels of procoagulants in cryoprecipitate, such as von Willebrand Factor (VWF) and factor VIII (FVIII), were highly variable, as was PMP activity. A standard cryoprecipitate dose contains significantly higher levels of measured plasminogen and D-dimer fragments than a standard HFC dose.
Conclusion
The tested HFC is a more reliable fibrinogen and FXIII source for accurate dosing compared with cryoprecipitate. Cryoprecipitate appears considerably less predictable for bleeding management due to wide variation in pro- and anticoagulation factors, the presence of PMPs, and the potential to elevate VWF and FVIII to prothrombotic levels.
Publisher
Public Library of Science (PLoS)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献