Performance of the cobas EZH2 mutation test on clinical samples from non-Hodgkin lymphoma patients

Author:

Shyu Johnny Y.,Schlag Peter A.ORCID,Karwowska Sylwia M.,Manohar Chitra F.ORCID,Truong Huan M.,Longshore John W.,Zhang Guili

Abstract

Objective To present the technical verification and clinical validation of the companion diagnostic assay, cobas® EZH2 Mutation Test (cobas EZH2 Test), targeting gain-of-function EZH2 mutations in follicular lymphoma (FL) and diffuse large B-cell lymphoma (DLBCL). The focus is on patient clinical samples proving that the test met the performance criteria required for FDA approval of a companion diagnostic test. Design Epizyme, Inc., Eisai Co., Ltd., and Roche Molecular Systems, Inc., collaborated to develop the cobas EZH2 Test on an RT-PCR platform. The assay design needed to detect the gain-of-function EZH2 mutations found in FL and DLBCL indications. Thus, the test was optimized for investigational purposes in a clinical trial setting. Part of its technical verification included testing of patient tumor samples with a documented diagnosis of FL and DLBCL procured from commercial vendors, and the clinical validation used patient samples from the Epizyme clinical study. Both the technical performance verification method correlation study (104 clinical commercially acquired samples) and the clinical validation accuracy study (341 patient samples from the therapeutic study) used next-generation sequencing as a reference method to establish true vs. false results by cobas EZH2 Test. The reproducibility study used a 15-member panel of DNA samples with varying EZH2 mutation status from procured clinical FL and DLBCL patient samples under multiple variables. Results Single and rare, infrequent double EZH2 mutations were detected in FL and DLBCL samples. Agreements between results from cobas EZH2 and sequencing were >98% from commercial clinical samples and from the therapeutic study clinical samples. The reproducibility study obtained 178 to 180 valid results for each panel member, with an overall invalid rate of 0.37%. The agreement for each per panel member was 100%. Conclusion cobas EZH2 Test data demonstrated that the test is reliable and will perform well in a commercial customer environment.

Funder

Roche Molecular Systems, Inc., Pleasanton, California, USA

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3