Background In elderly patients, displaced femoral neck fractures are mostly treated by arthroplasty; however for younger patients (<50 years), open reduction and internal fixation is considered the gold standard approach. Despite there being no consensus on the specific procedure, everyday clinical practice in a level I trauma center has shown that postoperative maltorsion after internal fixation of femoral neck fractures can have a significantly worse impact on mobilization and outcome. Different methods for measurement of malrotations are reported in literature. However, any reported method for the assessment of a shaft malrotation in the femur does not work here. In femoral neck fractures, the pointer function of the femoral neck, which is absolutely essential for these techniques, is lost and cannot be set in relation to the condylar plane. These circumstances are not addressed in literature thus far. Therefore, we propose here a novel method to fill this diagnostic gap. Methods and findings Three investigators (1 orthopaedic surgeons and 2 radiologists) measured the torsion of 20 legs on 10 patients using the Jarret method and a new geometric technique. To determine the intraobserver reliability the torsional angles were calculated again after 3 months. We applied a new geometric technique, without the need to include the femoral condyles in the measurement, to directly measure the angulation. For torsional difference, the interrater reliability -ICC (interclass correlation) between all investigators was 0.887 (good) (significance level: 95%CI, 0.668–0.969; p<0.001), by using the method of Jarret et al. and 0.933 (good) for the novel technique (significance level: 95%CI, 0.802–0.982; p<0.001). If the examinations are classified according to the patient side, our data show that for established methods, an ICC between the examiners on the right lower extremity is 0.978 (good) (95%CI, 0.936–0.994; p<0.001) and that on the left extremity is 0.955 (good) (95%CI, 0.867–0.988; p<0.001). Comparing with the new method, the right side assumes an ICC of 0.971 (good) (95%CI, 0.914–0.992; p<0.001), while the left side assumes an ICC of 0.910 (good) (95%CI, 0,736–0.976; p<0.001). When it comes to the intraobserver reliability, the measured cohort shows a significant better ICC for the novel method compared to Jarrett et al, with 0.907 respectively 0.786 for comparison in torsional differences. Conclusion The established methods may fail in assessing this special aspect of malrotation after femoral neck fractures. Here, the method presented results in a significant difference between the injured and uninjured side and shows significant differences in results compared to conventional measurement methods. The inter- and intraobserver reliability determined in this study is excellent and even higher in the assessment of torsional differences than the established method. We believe that the measurement method presented in this study is a useful tool to objectify the postoperative deformities in this area and making therapy recommendations in the future.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference29 articles.

1. Accuracy of measurement of femoral anteversion in femoral shaft fractures using a computer imaging software: a cadaveric study;T Stübig;Arch Orthop Trauma Surg,2012

2. Femoral Malrotation Following Intramedullary Nail Fixation;JD Lindsey;JAAOS—Journal of the American Academy of Orthopaedic Surgeons,2011

3. Assessing Femoral Rotation: A Survey Comparison of Techniques;LS Marchand;Journal of Orthopaedic Trauma,2020

4. Torsionsfehlstellungen am Humerus;N Hawi;Unfallchirurg,2018

5. Behandlung von Torsionsabweichungen am Unterschenkel;P Keppler;Unfallchirurg,2018

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3