Left ventricular longitudinal strain variations assessed by speckle-tracking echocardiography after a passive leg raising maneuver in patients with acute circulatory failure to predict fluid responsiveness: A prospective, observational study

Author:

Roy ClemenceORCID,Duclos Gary,Nafati Cyril,Gardette Mickael,Lopez Alexandre,Pastene BrunoORCID,Gaudray Eliott,Boussuges Alain,Antonini François,Leone Marc,Zieleskiewicz Laurent

Abstract

Background An association was reported between the left ventricular longitudinal strain (LV-LS) and preload. LV-LS reflects the left cardiac function curve as it is the ratio of shortening over diastolic dimension. The aim of this study was to determine the sensitivity and specificity of LV-LS variations after a passive leg raising (PLR) maneuver to predict fluid responsiveness in intensive care unit (ICU) patients with acute circulatory failure (ACF). Methods Patients with ACF were prospectively included. Preload-dependency was defined as a velocity time integral (VTI) variation greater than 10% between baseline (T0) and PLR (T1), distinguishing the preload-dependent (PLD+) group and the preload-independent (PLD-) group. A 7-cycles, 4-chamber echocardiography loop was registered at T0 and T1, and strain analysis was performed off-line by a blind clinician. A general linear model for repeated measures was used to compare the LV-LS variation (T0 to T1) between the two groups. Results From June 2018 to August 2019, 60 patients (PLD+ = 33, PLD- = 27) were consecutively enrolled. The VTI variations after PLR were +21% (±8) in the PLD+ group and -1% (±7) in the PLD- group (p<0.01). Mean baseline LV-LS was -11.3% (±4.2) in the PLD+ group and -13.0% (±4.2) in the PLD- group (p = 0.12). LV-LS increased in the whole population after PLR +16.0% (±4.0) (p = 0.04). The LV-LS variations after PLR were +19.0% (±31) (p = 0.05) in the PLD+ group and +11.0% (±38) (p = 0.25) in the PLD- group, with no significant difference between the two groups (p = 0.08). The area under the curve for the LV-LS variations between T0 and T1 was 0.63 [0.48–0.77]. Conclusion Our study confirms that LV-LS is load-dependent; however, the variations in LV-LS after PLR is not a discriminating criterion to predict fluid responsiveness of ICU patients with ACF in this cohort.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference49 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3