Accuracy of autorefraction in an adult Indian population

Author:

Kumar Rajesh S.ORCID,Moe Caitlin A.,Kumar Deepak,Rackenchath Mahalakshmi V.,A. V. Sathi Devi,Nagaraj Sriharsha,Wittberg Dionna M.,Stamper Robert L.,Keenan Jeremy D.ORCID

Abstract

Purpose Autorefractors allow non-specialists to quickly assess refractive error, and thus could be a useful component of large-scale vision screening programs. In order to better characterize the role of autorefraction for public health outreach programs in resource-limited settings, the diagnostic accuracy of two autorefractors was assessed relative to subjective refraction in an adult Indian population. Methods An optometrist refracted a series of patients aged ≥50 years at an eye clinic in Bangalore, India using the Nidek ARK-900 autorefractor first, followed by the 3nethra Royal autorefractor, and then subjective refraction. The diagnostic accuracy of each autorefractor for myopia, hyperopia, and astigmatism was assessed using subjective refraction as the reference standard, and measures of agreement between refractions were calculated. Results A total of 197 eyes in 104 individuals (mean age 63 ± 8 years, 52% female) were evaluated. Both autorefractors produced spherical equivalent estimates that were on average more hyperopic than subjective refraction, with a measurement bias of +0.16 D (95%CI +0.09 to +0.23D) for Nidek and +0.42 D (95%CI +0.28 to +0.54D) for 3nethra. When comparing pairs of measurements from autorefraction and subjective refraction, the limits of agreement were approximately ±1D for the Nidek autorefractor and ±1.75D for the 3Nethra autorefractor. The sensitivity and specificity of detecting ≥1 diopter of myopia were 94.6% (95%CI 86.8–100%) and 92.5% (95%CI 88.9–97.5%) for the Nidek, and 89.2% (95%CI 66.7–97.4) and 77.5% (95%CI 71.2–99.4%) for the 3Nethra. The accuracy of each autorefractor increased at greater levels of refractive error. Conclusions The sensitivity and specificity of the Nidek autorefractor for diagnosing refractive error among adults ≥50 years in an urban Indian clinic was sufficient for screening for visually significant refractive errors, although the relatively wide limits of agreement suggest that subjective refinement of the eyeglasses prescription would still be necessary.

Funder

Fortisure Foundation

Research to Prevent Blindness

That Man May See

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference32 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3