Abstract
Objectives
Compliant surfaces beneath a casualty diminish the quality of cardiopulmonary resuscitation (CPR) in clinical environments. To examine this issue in a sporting environment, we assessed chest compression quality and rescuer exertion upon compliant sports safety matting.
Methods
Twenty-seven advanced life support providers volunteered (13 male/14 female; mass = 79.0 ± 12.5 kg; stature = 1.77 ± 0.09 m). Participants performed 5 × 2 min, randomized bouts of continuous chest compressions on a mannequin, upon five surfaces: solid floor; low-compliance matting; low-compliance matting with a backboard; high-compliance matting; high-compliance matting with a backboard. Measures included chest compression depth and rate, percentage of adequate compressions, and rescuer heart rate and perceived exertion.
Results
Chest compression depth and rate were significantly lower upon high-compliance matting relative to other surfaces (p<0.05). The percentage of adequate compressions (depth ≥50 mm) was lowest upon high-compliance matting (40 ± 39%) versus low-compliance matting (60 ± 36%) and low-compliance matting with a backboard (59 ± 39%). Perceived exertion was significantly greater upon high-compliance matting versus floor, low-compliance matting, and low-compliance matting with a backboard (p<0.05).
Conclusion
Providers of CPR should be alerted to the detrimental effects of compliant safety matting in a sporting environment and prepare to alter the targeted compression depth and rescuer rotation intervals accordingly.
Publisher
Public Library of Science (PLoS)
Cited by
2 articles.