Regional distribution of computed tomography attenuation across the lumbar endplate

Author:

Segami KazuyukiORCID,Espinoza Orías Alejandro A.ORCID,Miyamoto Hiroe,Kanzaki Koji,An Howard S.,Inoue Nozomu

Abstract

The vertebral endplate forms a structural boundary between intervertebral disc and the trabecular bone of the vertebral body. As a mechanical interface between the stiff bone and resilient disc, the endplate is the weakest portion of the vertebral-disc complex and is predisposed to mechanical failure. However, the literature concerning the bone mineral density (BMD) distribution within the spinal endplate is comparatively sparse. The objective of this study is to investigate the three-dimensional (3D) distribution of computed tomography (CT) attenuation across the lumbosacral endplate measured in Hounsfield Units (HU). A total of 308 endplates from 28 cadaveric fresh-frozen lumbosacral spines were used in this study. Each spine was CT-scanned and the resulting DICOM data was used to obtain HU values of the bone endplate. Each individual endplate surface was subdivided into five clinically-relevant topographic zones. Attenuation was analyzed by spinal levels, sites (superior or inferior endplate) and endplate region. The highest HU values were found at the S1 endplate. Comparisons between the superior and inferior endplates showed the HU values in inferior endplates were significantly higher than those in the superior endplates within the same vertebra and the HU values in endplates cranial to the disc were significantly higher than those in the endplates caudal to the disc within the same disc. Attenuation in the peripheral region was significantly higher than in the central region by 32.5%. Regional comparison within the peripheral region showed the HU values in the posterior region were significantly higher than those in the anterior region and the HU values in the left region were significantly higher than those in the right region. This study provided detailed data on the regional HU distribution across the lumbosacral endplate, which can be useful to understand causes of some endplate lesions, such as fracture, and also to design interbody instrumentation.

Funder

National Institute of Arthritis and Musculoskeletal and Skin Diseases

National Center for Complementary and Alternative Medicine

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3