The effect of acute ventilation-perfusion mismatch on respiratory heat exchange in a porcine model

Author:

Edlinger-Stanger MaximilianORCID,Bernardi Martin-Hermann,Kovacs Katharina,Mascha Michael,Neugebauer Thomas,Böhme Stefan,Ayoubi Nathan,Christofi Nico,Garry James,Fleming Neal,Hiesmayr Michael

Abstract

Background Respiratory heat exchange is an important physiological process occurring in the upper and lower respiratory tract and is usually completed when inspired gases reach the alveoli. Animal and human studies demonstrated that heat exchange can be modulated by altering pulmonary ventilation and perfusion. The purpose of this study was to examine the effect of acute ventilation-perfusion (V/Q) mismatch on respiratory heat exchange. In clinical practice, monitoring respiratory heat exchange might offer the possibility of real-time tracking of acute V/Q-mismatch. Methods In 11 anesthetized, mechanically ventilated pigs, V/Q-mismatch was established by means of four interventions: single lung ventilation, high cardiac output, occlusion of the left pulmonary artery and repeated whole-lung lavage. V/Q-distributions were determined by the multiple inert gas elimination technique (MIGET). Respiratory heat exchange was measured as respiratory enthalpy using the novel, pre-commercial VQm monitor (development stage, Rostrum Medical Innovations, Vancouver, CA). According to MIGET, shunt perfusion of low V/Q compartments increased during single lung ventilation, high cardiac output and whole-lung lavage, whereas dead space and ventilation of high V/Q compartments increased during occlusion of the left pulmonary artery and whole-lung lavage. Results Bohr dead space increased after pulmonary artery occlusion and whole-lung lavage, venous admixture increased during single lung ventilation and whole-lung lavage, PaO2/FiO2 was decreased during all interventions. MIGET confirmed acute V/Q-mismatch. Respiratory enthalpy did not change significantly despite significant acute V/Q-mismatch. Conclusion Clinically relevant V/Q-mismatch does not impair respiratory heat exchange in the absence of additional thermal stressors and may not have clinical utility in the detection of acute changes.

Funder

Medical University of Vienna

Rostrum Medical Innovations

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3