Association between the donor to recipient ICG-PDR variation rate and the functional recovery of the graft after orthotopic liver transplantation: A case series

Author:

Cherchi Vittorio,Vetrugno Luigi,Terrosu Giovanni,Zanini Victor,Ventin MarcoORCID,Pravisani Riccardo,Tumminelli Francesco,Brollo Pier Paolo,Boscolo Erica,Peressutti Roberto,Lorenzin Dario,Bove TizianaORCID,Risaliti Andrea,Baccarani Umberto

Abstract

Background Despite current advances in liver transplant surgery, post-operative early allograft dysfunction still complicates the patient prognosis and graft survival. The transition from the donor has not been yet fully understood, and no study quantifies if and how the liver function changes through its transfer to the recipient. The indocyanine green dye plasma disappearance rate (ICG-PDR) is a simple validated tool of liver function assessment. The variation rate between the donor and recipient ICG-PDR still needs to be investigated. Materials and methods Single-center retrospective study. ICG-PDR determinations were performed before graft retrieval (T1) and 24 hours after transplant (T2). The ICG-PDR relative variation rate between T1 and T2 was calculated to assess the graft function and suffering/recovering. Matched data were compared with the MEAF model of graft dysfunction. Objective To investigate whether the variation rate between the donor ICG-PDR value and the recipient ICG-PDR measurement on first postoperative day (POD1) can be associated with the MEAF score. Results 36 ICG-PDR measurements between 18 donors and 18 graft recipients were performed. The mean donor ICG-PDR was 22.64 (SD 6.35), and the mean receiver’s ICG-PDR on 1st POD was 17.68 (SD 6.60), with a mean MEAF value of 4.51 (SD 1.23). Pearson’s test stressed a good, linear inverse correlation between the ICG-PDR relative variation and the MEAF values, correlation coefficient -0.580 (p = 0.012). Conclusion The direct correlation between the donor to recipient ICG-PDR variation rate and MEAF was found. Measurements at T1 and T2 showed an up- or downtrend of the graft performance that reflect the MEAF values.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3