The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests

Author:

Tengtrisorn S.ORCID,Tungsattayathitthan A.,Na Phatthalung S.,Singha P.,Rattanalert N.,Bhurachokviwat S.,Chouyjan S.

Abstract

Objective To compare the angle of deviation measured from Photo-Hirschberg testing and Krimsky testing, with that from an alternate prism cover test (APCT) in strabismus patients. Methods A cross-sectional study was conducted in Songklanagarind Hospital, Thailand. Thirty-three strabismus patients were photographed for analysis by Photo-Hirschberg testing using computer software. The corneal light reflex displacement, converted into prism diopter (PD), was compared to the angle of deviation measured with APCT. Twenty-eight strabismus patients were tested with the Krimsky test. Data were analyzed using Pearson correlation and paired t-tests. The study excluded 4 intermittent exotropia cases, 1 intermittent esotropia case and 2 which cases missing data for krimsky test. Results The mean±SD of the deviation angle, measured by APCT with a fixation target at 30 cm and 6 m; were 48.09±16.34PD and 47.82±15.73 PD, respectively. At 1 m, the difference in the angle of deviation measured from APCT and the Photo-Hirschberg test within 10 PD were 58.8% and 63.6%, for ET and XT, respectively. The difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 86.7% and 80.0%, respectively. At 4 m, the difference in angle of deviation measured from APCT and Photo-Hirschberg tests within 10 PD in ET and XT were 58.8% and 54.5%, respectively; whereas, the difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 80.0% and 70.0%, respectively. Conclusion The reliability of Krimsky test was better than Photo-Hirschberg test for measuring an angle of deviation.

Funder

Faculty of Medicine, Prince of Songkla University

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference22 articles.

1. Tests for detecting strabismus in children aged 1 to 6 years in the community;S Hull;Cochrane Database Syst Rev,2017

2. The calibration of the corneal light reflex to estimate the degree of an angle of deviation;S Tengtrisorn;J Med Assoc Thai,2015

3. Biostatistics 104: correlational analysis;YH Chan;Singap Med J,2003

4. Field testing of the plusoptiX S04 photoscreener;BW Arthur;Journal of AAPOS,2009

5. Calibration of Hirschberg test photographs under clinical conditions;PA DeRespinis;Ophthalmology,1989

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3