CardiOvascular examination in awake Orangutans (Pongo pygmaeus pygmaeus): Low-stress Echocardiography including Speckle Tracking imaging (the COOLEST method)

Author:

Chetboul ValérieORCID,Concordet Didier,Tissier Renaud,Vonfeld Irène,Poissonnier Camille,Alvarado Maria Paz,Passavin Peggy,Gluntz Mathilde,Lefort Solène,Bourgeois Aude,Duby Dylan,Hano Christelle,Chai Norin

Abstract

Introduction Cardiovascular diseases have been identified as a major cause of mortality and morbidity in Borneo orangutans (Pongo pygmaeus pygmaeus). Transthoracic echocardiography is usually performed under anesthesia in great apes, which may be stressful and increase risks of peri-anesthetic complications in case of cardiac alteration. The aim of the present pilot study was hence to develop a quick and non-stressful echocardiographic method (i.e., the COOLEST method) in awake Borneo orangutans (CardiOvascular examination in awake Orangutans: Low-stress Echocardiography including Speckle Tracking imaging) and assess the variability of corresponding variables. Materials and methods Four adult Borneo orangutans trained to present their chest to the trainers were involved. A total of 96 TTE examinations were performed on 4 different days by a trained observer examining each orangutan 6 times per day. Each examination included four two-dimensional views, with offline assessment of 28 variables (i.e., two-dimensional (n = 12), M-mode and anatomic M-mode (n = 6), Doppler (n = 7), and speckle tracking imaging (n = 3)), representing a total of 2,688 measurements. A general linear model was used to determine the within-day and between-day coefficients of variation. Results Mean±SD (minimum-maximum) images acquisition duration was 3.8±1.6 minutes (1.3–6.3). All within-day and between-day coefficients of variation but one (n = 55/56, 98%) were <15%, and most (51/56, 91%) were <10% including those of speckle tracking systolic strain variables (2.7% to 5.4%). Discussion Heart morphology as well as global and regional myocardial function can be assessed in awake orangutans with good to excellent repeatability and reproducibility. Conclusions This non-stressful method may be used for longitudinal cardiac follow-up in awake orangutans.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference21 articles.

1. Surgical repair of an atrial septal defect in a juvenile Sumatran orangutan (Pongo pygmaeus sumatraensis).;MJ Greenberg;J Zoo Wildl Med,1999

2. Evaluation of a ventricular septal defect in an orangutan: a case report;RA Cook;J Med Primatol,1986

3. A retrospective review of great ape cardiovascular disease epidemiology and pathology.;V Strong;Int Zoo Yearb,2018

4. Coxsackievirus B myocarditis in an orangutan;J Miyagi;Vet Pathol,1999

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3