Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Author:

Santiago AlfonsoORCID,Butakoff ConstantineORCID,Eguzkitza BeatrizORCID,Gray Richard A.ORCID,May-Newman KarenORCID,Pathmanathan PrasORCID,Vu Vi,Vázquez MarianoORCID

Abstract

Background Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. Methods The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow Q A o a v g, maximum aortic root flow Q A o m a x, average LVAD flow Q V A D a v g, and maximum LVAD flow Q V A D m a x); (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Results Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. Conclusions This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

Funder

U.S. Food and Drug Administration - Critical path initiative

Horizon 2020 Framework Programme

NeoTec 2019 - “Generador de Corazones virtuales”

Ministerio de Economía y Competitividad - Programa Torres-Quevedo

Publisher

Public Library of Science (PLoS)

Subject

Computational Theory and Mathematics,Cellular and Molecular Neuroscience,Genetics,Molecular Biology,Ecology,Modeling and Simulation,Ecology, Evolution, Behavior and Systematics

Reference74 articles.

1. Heart disease and stroke statistics—2019 update: a report from the American Heart Association;EJ Benjamin;Circulation,2019

2. Advanced (stage D) heart failure: a statement from the Heart Failure Society of America Guidelines Committee;JC Fang;Journal of cardiac failure,2015

3. Cardiac transplantation in the United States: an analysis of the UNOS registry;MJ Everly;Clinical transplants,2008

4. Results of the destination therapy post-food and drug administration approval study with a continuous flow left ventricular assist device: a prospective study using the INTERMACS registry (Interagency Registry for Mechanically Assisted Circulatory Support);UP Jorde;Journal of the American College of Cardiology,2014

5. Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome;Y Topilsky;Circulation: Cardiovascular Imaging,2011

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献