Impact of the suboptimal communication network environment on telerobotic surgery performance and surgeon fatigue

Author:

Akasaka HarueORCID,Hakamada KenichiORCID,Morohashi Hajime,Kanno Takahiro,Kawashima Kenji,Ebihara Yuma,Oki EijiORCID,Hirano Satoshi,Mori Masaki

Abstract

Background Remote surgery social implementation necessitates achieving low latency and highly reliable video/operation signal transmission over economical commercial networks. However, with commercial lines, communication bandwidth often fluctuates with network congestion and interference from narrowband lines acting as bottlenecks. Therefore, verifying the effects on surgical performance and surgeon fatigue when communication lines dip below required bandwidths are important. Objectives To clarify the communication bandwidth environment effects on image transmission and operability when bandwidth is lower than surgical robot requirements, and to determine surgeon fatigue levels in suboptimal environments. Methods Employing a newly developed surgical robot, a commercial IP-VPN line connected two hospitals 150 km apart. Thirteen surgical residents remotely performed a defined suturing procedure at 1-Gbps to 3-Mbps bandwidths. Communication delay, packet loss, time-to-task completion, forceps-movement distance, video degradation, and robot operability were evaluated before and after bandwidth changes. The Piper Fatigue Score-12 (PFS-12) was used to measure fatigue associated with surgeon performance. Results Roundtrip communication time for both 1-Gbps and 3-Mbps lines averaged 4 ms. Video transmission delay from camera to monitor was comparable, at 92 ms. Surgical robot signal transmission rate averaged 5.2 Mbps, so changing to 1-Gbps-3-Mbps lines resulted in significant packet loss. Surgeons perceived significant roughness, image distortion, diplopia, and degradation of 3D images (p = 0.009), but not changes in delay time or maneuverability. All surgeons could complete tasks, but objective measurement of task-completion time and forceps-travel distance were significantly prolonged (p = 0.013, p = 0,041). Additionally, PFS-12 showed post-procedure fatigue increase at both 1-Gbps and 3-Mbps. Fatigue increase was significant at 3-Mbps (p = 0.041). Conclusions In remote surgery environments with less than the optimal bandwidth, even when delay time and operability are equivalent, reduced surgical performance occurs from video degradation from packet loss. This may cause increased surgeon fatigue.

Funder

Japan Agency for Medical Research and Development

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3