Performance estimation of two in-house ELISA assays for COVID-19 surveillance through the combined detection of anti-SARS-CoV-2 IgA, IgM, and IgG immunoglobulin isotypes

Author:

Ramírez-Reveco AlfredoORCID,Velásquez Gerardo,Aros Christopher,Navarrete Gabriela,Villarroel-Espíndola Franz,Navarrete Maritza,Fica Alberto,Plaza Anita,Castro Natalia,Verdugo Claudio,Acosta-Jamett GerardoORCID,Verdugo Cristóbal C.ORCID

Abstract

The main objective of this study was to estimate the performance, under local epidemiological conditions, of two in-house ELISA assays for the combined detection of anti-SARS-CoV-2 IgA, IgM, and IgG immunoglobulins. A total of 94 serum samples were used for the assessment, where 44 corresponded to sera collected before the pandemic (free of SARS-CoV-2 antibodies), and 50 sera were collected from confirmed COVID-19 patients admitted to the main public hospital in the city of Valdivia, southern Chile. The Nucleocapsid (Np) and the receptor-binding domain (RBD) proteins were separately used as antigens (Np and RBD ELISA, respectively) to assess their diagnostic performance. A receiver operating characteristic (ROC) analysis was performed to estimate the optical density (OD) cut-off that maximized the sensitivity (Se) and specificity (Sp) of the ELISA assays. Np ELISA had a mean Se of 94% (95% CI = 83.5–98.8%) and a mean Sp of 100% (95% CI = 92.0–100%), with an OD 450 nm positive cut-off value of 0.88. On the other hand, RBD ELISA presented a mean Se of 96% (95% CI = 86.3–99.5%) and a mean Sp of 90% (95% CI = 78.3–97.5%), with an OD 450 nm positive cut off value of 0.996. Non-significant differences were observed between the Se distributions of Np and RBD ELISAs, but the latter presented a significant lower Sp than Np ELISA. In parallel, collected sera were also analyzed using a commercial lateral flow chromatographic immunoassay (LFCI), to compare the performance of the in-house ELISA assays against a commercial test. The LFCI had a mean sensitivity of 94% (95% CI = 87.4–100%) and a mean specificity of 100% (95% CI = 100–100%). When compared to Np ELISA, non-significant differences were observed on the performance distributions. Conversely, RBD ELISA had a significant lower Sp than the LFCI. Although, Np ELISA presented a similar performance to the commercial test, this was 2.5 times cheaper than the LFCI assay (labor cost not considered). Thus, the in-house Np ELISA could be a suitable alternative tool, in resource limited environments, for the surveillance of SARS-CoV-2 infection, supporting further epidemiological studies.

Funder

Agencia Nacional de Investigación y Desarrollo

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference36 articles.

1. WHO. COVID-19 Weekly Epidemiological Update. In: WHO COVID-19 Weekly Epidemiological Update, Edition 94 [Internet]. 2022 p. 10. https://www.who.int/publications/m/item/weekly-epidemiological-update-on-covid-19---1-june-2022

2. MINSAL. Cifras Oficiales COVID-19. 2022. https://www.gob.cl/coronavirus/cifrasoficiales/

3. Transmission dynamics and control of COVID-19 in Chile, March-October, 2020;A Tariq;PLoS Negl Trop Dis,2021

4. A serological assay to detect SARS-CoV-2 seroconversion in humans;F Amanat;Nat Med,2020

5. Characteristics of anti-sars-cov-2 antibodies in recovered covid-19 subjects;A Huynh;Viruses,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3