Analysis of water quality over non-condensable gases concentration on steam used for sterilization

Author:

Miguel Emerson Aparecido,Laranjeira Paulo Roberto,Ishii MarinaORCID,Pinto Terezinha de Jesus Andreoli

Abstract

Background Non-condensable gases (NCGs) are all gases that do not undergo liquefaction during the saturated steam sterilization process. During a sterilization cycle, the NCGs presence inside the chamber is one of the biggest threats to the sterilization process compromising process validation and product quality. Methods In this work, 170 testing of NCGs concentrations performed between September 2016 and August 2021 were carried out by Orionce Serviços de Metrologia Ltda (Barueri, SP, Brazil), according to EN285:2015 procedure. For steam generation, the types of water used were softened water (SW), one-step reverse osmosis (RO), purified water (PW), and water for injection (WFI). The data obtained were analyzed using Minitab® software, version 18.1, to identify a relationship between the water quality used for steam generation and the concentration of non-condensable gases determined into equipment qualification. Findings From total tests performed, 109 tests passed, and 61 tests failed, representing 64.2% and 35.8%, respectively. A higher failure rate was observed in terms of concentration of non-condensable gases in systems that used purified water for steam generation (64.7%), followed by softened water (55.6%), one-step reverse osmosis (42.9%), and water for injection (7.6%). Conclusion System processes using WFI for steam generation showed better results for steam quality approvement, in terms of NCGs concentration, compared to softened, purified, or reverse osmosis water treatments in the concentration of non-condensable gases in steam used for sterilization processes of industrial utilities.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference32 articles.

1. Steam sterilization principles;M Dion;Pharm Eng,2013

2. Best practices for autoclave validation: steam quality testing;I. Soto;IVT Network,2020

3. Reason behind wet pack after steam sterilization and its consequences: an overview from Central Sterile Supply Department of a cancer center in eastern India;D. Basu;J Infect Public Health,2017

4. Troubleshooting failed sterilization loads: process failures and wet packs/loads.;R. Seavey;Am J Infect Control,2016

5. Sterilization–Steam sterilizers–Large sterilizers. Document EN 285; 2015. European Committee for Standardization website. http://www.cen.eu. Published 2015