Development of deep learning-assisted overscan decision algorithm in low-dose chest CT: Application to lung cancer screening in Korean National CT accreditation program

Author:

Kim SihwanORCID,Jeong Woo KyoungORCID,Choi Jin Hwa,Kim Jong Hyo,Chun MinsooORCID

Abstract

We propose a deep learning-assisted overscan decision algorithm in chest low-dose computed tomography (LDCT) applicable to the lung cancer screening. The algorithm reflects the radiologists’ subjective evaluation criteria according to the Korea institute for accreditation of medical imaging (KIAMI) guidelines, where it judges whether a scan range is beyond landmarks’ criterion. The algorithm consists of three stages: deep learning-based landmark segmentation, rule-based logical operations, and overscan determination. A total of 210 cases from a single institution (internal data) and 50 cases from 47 institutions (external data) were utilized for performance evaluation. Area under the receiver operating characteristic (AUROC), accuracy, sensitivity, specificity, and Cohen’s kappa were used as evaluation metrics. Fisher’s exact test was performed to present statistical significance for the overscan detectability, and univariate logistic regression analyses were performed for validation. Furthermore, an excessive effective dose was estimated by employing the amount of overscan and the absorbed dose to effective dose conversion factor. The algorithm presented AUROC values of 0.976 (95% confidence interval [CI]: 0.925–0.987) and 0.997 (95% CI: 0.800–0.999) for internal and external dataset, respectively. All metrics showed average performance scores greater than 90% in each evaluation dataset. The AI-assisted overscan decision and the radiologist’s manual evaluation showed a statistically significance showing a p-value less than 0.001 in Fisher’s exact test. In the logistic regression analysis, demographics (age and sex), data source, CT vendor, and slice thickness showed no statistical significance on the algorithm (each p-value > 0.05). Furthermore, the estimated excessive effective doses were 0.02 ± 0.01 mSv and 0.03 ± 0.05 mSv for each dataset, not a concern within slight deviations from an acceptable scan range. We hope that our proposed overscan decision algorithm enables the retrospective scan range monitoring in LDCT for lung cancer screening program, and follows an as low as reasonably achievable (ALARA) principle.

Funder

Korea Medical Device Development Fund

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3