Visualization of dental plaque with a 3D-intraoral-scanner—A tool for whole mouth planimetry

Author:

Jung KatjaORCID,Giese-Kraft Katja,Fischer Melanie,Schulze Kai,Schlueter Nadine,Ganss Carolina

Abstract

Planimetry is a reliable method for detecting and monitoring plaque. Until now, this method has mainly been applied to conventional-camera images, which is difficult and time-consuming in relation to the entire dentition. Today, 3D-intraoral-scans are well suited for imaging the entire dentition and are therefore an efficient and feasible alternative. 3D-intraoral-scans have already proven successful for the quantification of plaque based on a plaque index. Therefore, aim of this study was to investigate whether images from 3D-intraoral-scans are also suitable for valid planimetric plaque measurements and monitoring; intraoral-camera images served as a reference. Twenty subjects (27.5±1.2 years) were included. Plaque was disclosed at three different time points: habitual plaque (T1), after 72 h without oral hygiene (T2) and after subsequent tooth brushing (T3) and quantified using 3D-intraoral-scans and intraoral-camera images (intraoral-camera CS 1500, intraoral-scanner CS 3600; Carestream Dental, Germany). The percentage of the plaque-covered surface of the total surface area (P%) was determined with a software specially programmed for this purpose using images from 3D-intraoral-scans of the oral and vestibular surfaces of the Ramfjord teeth (16, 21, 24, 36, 41, and 44); the intraoral-camera images of the vestibular surfaces of 16 and 36 served as reference. P% from images of the 3D-intraoral-scan and the intraoral-camera revealed a very good correlation (r = 0.876; p ≤ 0.001); the Bland-Altmann analysis showed a good agreement with no proportional and a very minor systematic bias with slightly higher values from images of the 3D-intraoral-scan. Further, P% measurements of the images of the 3D-intraoral-scan were able to detect changes in plaque levels, showing a 47% (p ≤ 0.001) increase in P% from T1 to T2 and a 43% (p ≤ 0.001) decrease after toothbrushing (T3). Planimetry using images of the 3D-intraoral-scan seems to be a suitable tool for whole mouth planimetry to record and monitor dental plaque.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3