Effect of an optimized X-ray blanket design on operator radiation dose in cardiac catheterization based on real-world angiography

Author:

Davidsen CedricORCID,Bolstad Kirsten,Ytre-Hauge Kristian,Samnøy Andreas TefreORCID,Vikenes Kjell,Tuseth Vegard

Abstract

Background There is increasing concern and focus in the interventional cardiology community on potential long term health issues related to radiation exposure and heavy wearable protection. Optimized shielding measures may reduce operator dose to levels where lighter radioprotective garments can safely be used, or even omitted. X-ray blankets (XRB) are commercially available but suffer from small size and lack of stability. A larger XRB may reduce operator dose but could hamper vascular access and visualization. The aim of this study is to assess shielding effect of an optimized XRB during cardiac catheterization and estimate the potential reduction in annual operator dose based on DICOM Radiation Dose Structured Report (RDSR) data reflecting everyday clinical practice. Methods Data accumulated from 7681 procedures over three years in our RDSR repository was used to identify projection angles and radiation doses during cardiac catheterization. Using an anthropomorphic phantom and a scatter radiation detector, radiation dose to the operator (mSv) and patient (dose area product—DAP) was measured for each angiographic projection for three different shielding setups. Relative operator dose (mSv/DAP) was calculated and multiplied by DAP per projection to estimate effect on operator dose. Results Adding an optimized XRB to a standard shielding setup comprising a table- and ceiling-mounted shield resulted in a 94.9% reduction in estimated operator dose. The largest shielding effect was observed in left and cranial projections where the ceiling-mounted shield offered less protection. Conclusions An optimized XRB is a simple shielding measure that has the potential to reduce operator dose.

Funder

Grieg Foundation

Helse Vest

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference13 articles.

1. Temporal Trends in X-Ray Exposure during Coronary Angiography and Percutaneous Coronary Intervention;C Davidsen;Journal of interventional cardiology,2020

2. Occupational hazards of interventional cardiologists: prevalence of orthopedic health problems in contemporary practice;JA Goldstein;Catheterization and cardiovascular interventions: official journal of the Society for Cardiac Angiography & Interventions,2004

3. A novel complete radiation protection system eliminates physician radiation exposure and leaded aprons;P Fattal;Catheterization and cardiovascular interventions: official journal of the Society for Cardiac Angiography & Interventions,2013

4. Efficacy of the RADPAD Protection Drape in Reducing Operators’ Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial;W Vlastra;Circulation Cardiovascular interventions,2017

5. Randomized Controlled Trial of Radiation Protection With a Patient Lead Shield and a Novel, Nonlead Surgical Cap for Operators Performing Coronary Angiography or Intervention;A Alazzoni;Circulation Cardiovascular interventions,2015

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3