Abstract
Scenario models of a moving subway train can help investigate the influence of different fire locations on smoke propagation characteristics in curved tunnels. To this end, this study adopts the three-dimensional Unsteady Reynolds Average Navier-Stokes equations method and the renormalization group k-ε two-equation turbulence model with buoyancy correction for numerical analysis. The motion of the train is replicated using the slip grid technique. The results indicate that when a fire breaks out on a moving train in tunnels, the piston wind leads the longitudinal movement of the smoke. If a fire erupts in the head or middle car of a moving train, the time of smoke backflow is delayed by 30 s or 17 s, respectively, compared to that for the tail car. The obtained results provide a theoretical basis for reasonably controlling the smoke flow in subway tunnels and reducing casualties in fire accidents.
Funder
National Numerical Wind Tunnel Project
Fundamental Research Funds for Central Universities of the Central South University
Publisher
Public Library of Science (PLoS)
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献