Research on the relationship between the scattering contribution and physical factors of the reference radiation regulated by ISO 4037–1

Author:

Qian Yi-kunORCID,Liu Yi-xin,Mao Ben-jiang,Zhang Song,Liu Yanan,Feng PengORCID

Abstract

In the latest version of ISO 4037–1:2019 standard, the minimum dimension of a gamma radiation reference field was not clearly specified, which makes the construction of a minitype gamma reference radiation field lack of scientific basis. This paper carried out the research on the relationship between the scattering contribution and physical factors of the reference radiation regulated by ISO 4037–1. LS-SVM was applied to construct the relational model between physical factors and scattering contribution based on the data simulated by Monte Carlo method. Then the minimum dimension of collimated reference radiation field is obtained by PSO algorithm. For Co-60 source, the minimum size of the radiation field obtained is 93 cm(L)×40 cm(W)×40 cm(H). For Cs-137 source, the minimum size of the radiation field obtained is 153 cm(L)×47 cm (W)×47 cm(H). The results meet the requirements of the standard based on the model and provides a technical reference for the design of a minitype reference radiation field.

Funder

Chongqing Technological Innovation and Application Development Project

Chongqing Postgraduate Research and Innovation Project

Fundamental and Frontier Research Project of Chongqing

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference23 articles.

1. Radiation protection instrumentation-Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation-Part 1: Portable workplace and environmental meters and monitors;IEC 60846,2009

2. X and gamma reference radiation for calibration dosimeters and dose rate meters and for determining their response as a function of photon energy: I. Radiation characteristics and production methods;ISO 4037–1,2019

3. X and gamma reference radiation for calibration dosimeters and dose rate meters and for determining their response as a function of photon energy: II. Dosimetry for radiation protection over the energy ranges 8 keV to 1.3 MeV and 4 MeV to 9 MeV;ISO 4037–2,2019

4. X and gamma reference radiation for calibration dosimeters and dose rate meters and for determining their response as a function of photo energy: III. Calibration of area and personal dosimeters and the measurement of their response as a function of energy and angle of incidence;ISO 4037–3,2019

5. X and gamma reference radiation for calibration dosimeters and dose rate meters and for determining their response as a function of photo energy: IV. Calibration of area and personal dosimeters in low energy X reference radiation fields;ISO 4037–4,2019

同舟云学术