Determination of the optimum definition of growth evaluation for indeterminate pulmonary nodules detected in lung cancer screening

Author:

Lee Jong Hyuk,Hwang Eui JinORCID,Lim Woo Hyeon,Goo Jin MoORCID

Abstract

Objective To determine the optimum definition of growth for indeterminate pulmonary nodules detected in lung cancer screening. Materials and methods Individuals with indeterminate nodules as defined by volume of 50–500 mm3 (solid nodules) and solid component volume of 50–500 mm3 or average diameter of non-solid component ≥8 mm (part-solid nodules) on baseline lung cancer screening low-dose chest CT (LDCT) were included. The average diameters and volumes of the nodules were measured on baseline and follow-up LDCTs with semi-automated segmentation. Sensitivities and specificities for lung cancer diagnosis of nodule growth defined by a) percentage volume growth ≥25% (defined in the NELSON study); b) absolute diameter growth >1.5 mm (defined in the Lung-RADS version 1.1); and c) subjective decision by a radiologist were evaluated. Sensitivities and specificities of diagnostic referral based on various thresholds of volume doubling time (VDT) were also evaluated. Results Altogether, 115 nodules (one nodule per individual; 93 solid and 22 part-solid nodules; 105 men; median age, 68 years) were evaluated (median follow-up interval: 201 days; interquartile range: 127–371 days). Percentage volume growth ≥25% exhibited higher sensitivity but lower specificity than those of diametrical measurement compared to absolute diameter growth >1.5 mm (sensitivity, 69.2% vs. 42.3%, p = 0.023; specificity, 82.0% vs. 96.6%, p = 0.002). The radiologist had an equivalent sensitivity (53.9%; p = 0.289) but higher specificity (98.9%; p = 0.002) compared to those of volume growth, but did not differ from those of diameter growth (p>0.05 both in sensitivity and specificity). Compared to the VDT threshold of 600 days (sensitivity, 61.5%; specificity, 87.6%), VDT thresholds ≤200 and ≤300 days exhibited significantly lower sensitivity (30.8%, p = 0.013) and higher specificity (94.4%, p = 0.041), respectively. Conclusion Growth evaluation of screening-detected indeterminate nodules with volumetric measurement exhibited higher sensitivity but lower specificity compared to diametric measurements.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3