Abstract
Swine atrophic rhinitis is a disease caused by Pasteurella multocida and Bordetella bronchiseptica that affects pigs. Inactivated vaccines containing the toxins produced by Pasteurella multocida and Bordetella bronchiseptica have been widely used for the prevention of swine atrophic rhinitis. The efficacy of a vaccine is correlated with the amount of antigen present; however, the protective toxin of P. multocida bound to aluminum hydroxide, which is used as an adjuvant, can hinder the monitoring of the antigen concentration in the vaccine. This study assessed the applicability of a dot immunoassay as an antigen quantification method using monoclonal antibodies. This quantification method was able to detect the antigen with high specificity and sensitivity even when the antigen was bound to the adjuvant, and its application to vaccine products revealed a correlation between the amount of antigen present in the vaccine and the neutralizing antibody titers induced in pigs. The antigen quantification method presented in this study is a simple and sensitive assay capable of quantifying the amount of antigen present in a vaccine that can be used as an alternative quality control measure.
Publisher
Public Library of Science (PLoS)