Handheld dynamometry: Validity and reliability of measuring hip joint rate of torque development and peak torque

Author:

McNabb KatherineORCID,Sánchez María B.ORCID,Selfe James,Reeves Neil D.ORCID,Callaghan Michael

Abstract

Introduction Measuring rate of torque development (RTD) and peak torque (PT) for hip muscle performance presents challenges in clinical practice. This study investigated the construct validity of a handheld dynamometer (HHD) versus an isokinetic dynamometer (IKD), and intra-rater repeated reliability for RTD and PT and their relationship in hip joint movements. Methods Thirty healthy individuals (mean age = 30 ± 8 years, 13 males) underwent two test sessions in a single day. RTD (0–50, 0–100, 0–150, 0-200ms) and PT normalised to body mass in maximal voluntary isometric contractions were measured using a HHD and an IKD in hip flexion, extension, abduction, adduction, internal and external rotation. Results For validity between the devices, RTD0-50 exhibited the largest significant systematic bias in all hip movements (3.41–11.99 Nm·s-1 kg-1) and widest limits-of-agreement, while RTD0-200 had the lowest bias (-1.33–3.99 Nm·s-1 kg-1) and narrowest limits-of-agreement. For PT, agreement between dynamometers was observed for hip flexion (0.08 Nm·kg-1), abduction (-0.09 Nm·kg-1), internal (-0.01 Nm·kg-1), and external rotation (0.05 Nm·kg-1). For reliability, intra-rater intraclass correlation coefficient (ICC2,1) ranged from moderate to good in RTD0-50 and RTD0-100 (0.5–0.88), and good to excellent in RTD0-150 and RTD0-200 (0.87–0.95) in all movements. The HHD displayed excellent intra-rater, relative reliability values (ICC2,1) in all movements (0.85–0.95). Pearson’s correlation revealed good linear correlation between PT and RTD0-150 and RTD0-200 in all movements (r = .7 to .87, p = < .001). Conclusion Validity analysis demonstrated significant systematic bias and lack of agreement in RTD measures between the HHD and IKD. However, the HHD displays excellent to moderate intra-rater, relative reliability for RTD and PT measures in hip movements. Clinicians may use the HHD for hip muscle PT assessment but note, late phase RTD measures are more reliable, valid, and relate to PT than early phase RTD. Additionally, the correlation between RTD and PT at various time epochs was examined to better understand the relationship between these measures.

Publisher

Public Library of Science (PLoS)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3