Fat quantification in dual-layer detector spectral CT: How to handle iron overload, varying tube voltage and radiation dose Indices

Author:

Molwitz IsabelORCID,Campbell Graeme Michael,Knopp Tobias,Schubert Niklas,Erley JenniferORCID,Löser Anastassia,Adam Gerhard,Yamamura Jin,Fischer Roland,Ozga Ann-Kathrin,Szwargulski Patryk

Abstract

Objectives Opposed to other spectral CT techniques, fat quantification in dual-layer detector CT (dlCT) has only recently been developed. The impact of concomitant iron overload and dlCT-specific protocol settings such as the dose right index (DRI), a measure of image noise and tube current, on dlCT fat quantification was unclear. Further, spectral information became newly available <120 kV. Therefore, this study’s objective was to evaluate the impact of iron, changing tube voltage, and DRI on dlCT fat quantification. Material and methods Phantoms with 0 and 8mg/cm3 iron; 0 and 5mg/cm3 iodine; 0, 10, 20, 35, 50, and 100% fat and liver equivalent, respectively, were scanned with a dlCT (CT7500, Philips, the Netherlands) at 100kV/20DRI, 120kV/20DRI, 140kV/20DRI, and at 120kV/16DRI, 120kV/24DRI. Material decomposition was done for fat, liver, and iodine (A1); for fat, liver, and iron (A2); and for fat, liver, and combined reference values of iodine and iron (A3). All scans were analyzed with reference values from 120kV/20DRI. For statistics, the intraclass correlation coefficient (ICC) and Bland-Altman analyses were used. Results In phantoms with iron and iodine, results were best for A3 with a mean deviation to phantom fat of 1.3±2.6% (ICC 0.999 [95%-confidence interval 0.996–1]). The standard approach A1 yielded a deviation of -2.5±3.0% (0.998[0.994–0.999]), A2 of 6.1±4.8% (0.991[0.974–0.997]). With A3 and changing tube voltage, the maximal difference between quantified fat and the phantom ground truth occurred at 100kV with 4.6±2.1%. Differences between scans were largest between 100kV and 140kV (2.0%[-7.1–11.2]). The maximal difference of changing DRI occurred between 16 and 24 DRI with 0.4%[-2.2–3.0]. Conclusion For dlCT fat quantification in the presence of iron, material decomposition with combined reference values for iodine and iron delivers the most accurate results. Tube voltage-specific calibration of reference values is advisable while the impact of the DRI on dlCT fat quantification is neglectable.

Funder

Forschungszentrum Medizintechnik Hamburg

Publisher

Public Library of Science (PLoS)

Reference24 articles.

1. Dual-Energy Computed Tomography for Fat Quantification in the Liver and Bone Marrow: A Literature Review;I Molwitz;Rofo,2020

2. Skeletal muscle fat quantification by dual-energy computed tomography in comparison with 3T MR imaging;I Molwitz;Eur Radiol,2021

3. Contrast-independent liver-fat quantification from spectral CT exams;PR Mendonca;Med Image Comput Comput Assist Interv,2013

4. Body composition measurement using computed tomography: Does the phase of the scan matter?;KE Rollins;Nutrition,2017

5. Differentiation of adrenal adenomas from adrenal metastases in single-phased staging dual-energy CT and radiomics;MT Winkelmann;Diagn Interv Radiol,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3