A comparative study of 3D measuring methods for monitoring breast volume changes

Author:

Dijkman Benthe A. M.,Liberton Niels P. T. J.,te Slaa Sjoerd,Smit Jan Maerten,Wiepjes Chantal M.,Dreijerink Koen M. A.ORCID,den Heijer Martin,Verdaasdonk Rudolf M.,de Blok Christel J. M.

Abstract

Three-dimensional (3D) imaging techniques are promising new tools for measuring breast volume, for example in gender-affirming therapy. Transgender individuals can be treated with gender-affirming hormone therapy (GAHT). A robust method for monitoring breast volume changes is critical to be able to study the effects of feminizing GAHT. The primary aim of this study was to compare the accuracy of three 3D devices (Vectra XT, Artec LEO and iPhone XR) for measuring modest breast volume differences using a mannequin. The secondary aim of this study was to evaluate these methods in several performance domains. We used reference prostheses of increasing volumes and compared the volumes using GOM-inspect software. For Vectra XT 3D images, manufacturer-provided software was used to calculate volumes as well. The scanning methods were ranked based on their performance in a total of five categories: volume estimations, costs, user-friendliness, test subject-friendliness and technical aspects. The 3D models analyzed with GOM-inspect showed relative mean estimate differences from the actual volumes of 9.1% for the Vectra XT, 7.3% for the Artec LEO and 14% for the iPhone XR. For the Vectra XT models analyzed with the built-in software this was 6.2%. Root mean squared errors (RMSE) calculated based on the GOM-inspect volume analyses showed mean RMSEs of 2.27, 2.54 and 8.93 for the Vectra XT, Artec LEO and iPhone XR, respectively. The Vectra software had a mean RMSE of 3.00. In the combined performance ranking, the Vectra XT had the most favorable ranking, followed by the Artec LEO and the iPhone XR. The Vectra XT and Artec LEO are the preferred scanners to monitor breast development due to the combination of higher accuracy and overall performance. The current study shows that 3D techniques can be used to adequately measure modest breast volume differences and therefore will be useful to study for example breast changes in transgender individuals using feminizing GAHT. These observations may also be relevant in other fields of 3D imaging research.

Publisher

Public Library of Science (PLoS)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3