Estimation of pulmonary vascular resistance for Glenn physiology

Author:

Laudenschlager SebastianORCID,Schofield Samuel,Drysdale Nicolas,Stone Matthew,Romanowicz Jennifer,Frank Benjamin,DiMaria Michael,Kheyfets Vitaly O.,Hedjazi-Moghari Mehdi

Abstract

Children with single ventricle heart disease typically require a series of three operations, (1) Norwood, (2) Glenn, and (3) Fontan, which ultimately results in complete separation of the pulmonary and systemic circuits to improve pulmonary/systemic circulation. In the last stage, the Fontan operation, the inferior vena cava (IVC) is connected to the pulmonary arteries (PAs), allowing the remainder of deoxygenated blood to passively flow to the pulmonary circuit. It is hypothesized that optimizing the Fontan anatomy would lead to decreased power loss and more balanced hepatic flow distribution. One approach to optimizing the geometry is to create a patient-specific digital twin to simulate various configurations of the Fontan conduit, which requires a computational model of the proximal PA anatomy and resistance, as well as the distal Pulmonary Vascular Resistance (PVR), at the Glenn stage. To that end, an optimization pipeline was developed using 3D computational fluid dynamics (CFD) and 0D lumped parameter (LP) simulations to iteratively refine the PVR of each lung by minimizing the simulated flow and pressure error relative to patients’ cardiac magnetic resonance (CMR) and catheterization (CATH) data. While the PVR can also be estimated directly by computing the ratio of pressure gradients and flow from CATH and CMR data, the computational approach can separately identify the different components of PVR along the Glenn pathway, allowing for a more detailed depiction of the Glenn vasculature. Results indicate good correlation between the optimized PVR of the CFD and LP models (n = 16), with an intraclass correlation coefficient (ICC) of 0.998 (p = 0.976) and 0.991 (p = 0.943) for the left and right lung, respectively. Furthermore, compared to CMR flow and CATH pressure data, the optimized PVR estimates result in mean outlet flow and pressure errors of less than 5%. The optimized PVR estimates also agree well with the computed PVR estimates from CATH pressure and CMR flow for both lungs, yielding a mean difference of less than 4%.

Funder

National Heart, Lung, and Blood Institute

Publisher

Public Library of Science (PLoS)

Reference34 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3