Abstract
The polymetallic mineral samples in Pan-Xi region are rich in rare earth resources, and exploring an efficient and accurate analysis method is of great significance for their comprehensive utilization. In this study, the samples were decomposed by three methods, namely closed acid dissolution, open acid dissolution with five acid and alkali fusion with sodium peroxide, and the 15 REE were determined by inductively coupled plasma mass spectrometry (ICP-MS) with Rh and Re as internal standard correction elements. The comparative experiments were conducted using standard substances, and the results showed: (1) The detection limit of closed acid dissolution method was low with relative standard deviation (RSD) ranging from 2.51% to 9.56% and the accuracy of method (ΔlgC) ranging from 0.006 to 0.073, while the sample processing was long, and the results of some REE were low. (2) The RSD of open acid dissolution with five acid method ranged from 1.93% to 7.96%, and ΔlgC ranged from 0.004 to 0.045 with low results of the determination results of REE. (3) The alkali fusion with sodium peroxide method eliminated the influence of matrix effects by selecting instrument optimization, sample dilution, appropriate internal standard elements, etc. The RSD ranged from 1.24% to 6.49%, and ΔlgC ranged from 0.001 to 0.032. In conclusion, alkali fusion with sodium peroxide method has a fast analysis process, complete sample dissolution, and the accuracy and precision of test results can meet the requirements of specification (DZ/T0011-2015), which is most suitable for the analysis of REE in polymetallic mineral samples from Pan-Xi region.
Funder
Open Foundation of the Key Laboratory of Natural Resource Coupling Process and Effects
Geological Survey Project of China Geological Survey
Publisher
Public Library of Science (PLoS)
Reference26 articles.
1. First discovery of ion adsorption-type (medium-heavy) REE deposit in the Panzhihua-Xichang area, Sichuan Province, and its significance;XH Xia;Geological Review,2022
2. Determination of fifteen rare earth elements by PW-1404 X-ray Fl-uorescence Spectromete;B Zhu;Environment and Exploitation,1997
3. Determination of eight major rare earth oxides in light rare earth ore by X-ray fluorescence spectrometry with fusion sample preparation;LL YU;Metallurgical Analysis. Metallurgical Analysis,2019
4. Determination of Major and Rare Earth Elements in Bastnasite Ores by ICP-AES;Serpil Yenisoy-Karakaş;Analytical Letters,2004