The plasma separation card as a novel solution for enhancing central laboratory capability for HIV-1 viral load monitoring in limited-access settings

Author:

Kiyaga Charles,Makoha Caroline,Nkugwa Ivan,Okiira Christopher,Okwir Richard,Gebreab Sirak ZenebeORCID,Suarez Patricia Rodriguez-Ventosa,LaBrot Benjamin,Durán Ana CarrascoORCID

Abstract

Measurement of HIV-1 viral load (VL) is essential for monitoring antiretroviral treatment (ART) efficacy. The preferred specimen type for VL is plasma, but in remote settings where collection and preservation of plasma many not be possible, dried blood spots (DBS) are often used instead. A new specimen collection matrix, the cobas plasma separation card (PSC, Roche Diagnostics Solutions), enables specimen preparation from a finger prick or venous blood, using a multi-layer absorption and filtration design that results in a specimen similar to dried plasma. We sought to confirm the correlation between VL results obtained using PSC prepared from venous blood to those from plasma or DBS, as well as PSC prepared with capillary blood from a finger prick. PSC, DBS and plasma were prepared with blood from HIV-1 infected persons attending a primary care clinic in Kampala, Uganda. VL in PSC and plasma was measured using cobas HIV-1 (Roche Diagnostics), while VL in DBS was measured with RealTime HIV-1 (Abbott Diagnostics). The correlation between VL from plasma and PSC made from capillary or venous blood was high (regression coefficient of determination r2 between 0.87 and 0.91), and there was good agreement based on mean bias (-0.14 to 0.24 log10 copies/mL) and classification of VL above or below 1000 copies/mL (91.4% agreement). In contrast, VL from DBS was lower than plasma or PSC (mean bias 0.51 to 0.63 log10 copies/mL) and not as well correlated (r2 0.78 to 0.81, 75.1–80.5% agreement). These results confirm the utility of PSC as an alternative specimen type for HIV-1 viral load measurement in areas where preparation and optimal storage or shipment of plasma is an obstacle to provision of treatment and care of HIV-1 infected people.

Funder

Roche Molecular Systems

Publisher

Public Library of Science (PLoS)

Reference27 articles.

1. Dried blood spots for HIV-1 drug resistance and viral load testing: A review of current knowledge and WHO efforts for global HIV drug resistance surveillance.;S Bertagnolio;AIDS Rev.,2010

2. HIV-1 drug resistance genotyping success rates and correlates of Dried-blood spots and plasma specimen genotyping failure in a resource-limited setting.;J Omooja;BMC Infect Dis,2022

3. Measurement of HIV-1 viral load for drug resistance surveillance using dried blood spots: literature review and modeling of contribution of DNA and RNA;NT Parkin;AIDS Rev,2014

4. Diagnostic Accuracy of Dried Plasma Spot Specimens for HIV-1 Viral Load Testing: A Systematic Review and Meta-analysis;Y Fong;J Acquir Immune Defic Syndr.,2022

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3