Abstract
Measurement of HIV-1 viral load (VL) is essential for monitoring antiretroviral treatment (ART) efficacy. The preferred specimen type for VL is plasma, but in remote settings where collection and preservation of plasma many not be possible, dried blood spots (DBS) are often used instead. A new specimen collection matrix, the cobas plasma separation card (PSC, Roche Diagnostics Solutions), enables specimen preparation from a finger prick or venous blood, using a multi-layer absorption and filtration design that results in a specimen similar to dried plasma. We sought to confirm the correlation between VL results obtained using PSC prepared from venous blood to those from plasma or DBS, as well as PSC prepared with capillary blood from a finger prick. PSC, DBS and plasma were prepared with blood from HIV-1 infected persons attending a primary care clinic in Kampala, Uganda. VL in PSC and plasma was measured using cobas HIV-1 (Roche Diagnostics), while VL in DBS was measured with RealTime HIV-1 (Abbott Diagnostics). The correlation between VL from plasma and PSC made from capillary or venous blood was high (regression coefficient of determination r2 between 0.87 and 0.91), and there was good agreement based on mean bias (-0.14 to 0.24 log10 copies/mL) and classification of VL above or below 1000 copies/mL (91.4% agreement). In contrast, VL from DBS was lower than plasma or PSC (mean bias 0.51 to 0.63 log10 copies/mL) and not as well correlated (r2 0.78 to 0.81, 75.1–80.5% agreement). These results confirm the utility of PSC as an alternative specimen type for HIV-1 viral load measurement in areas where preparation and optimal storage or shipment of plasma is an obstacle to provision of treatment and care of HIV-1 infected people.
Publisher
Public Library of Science (PLoS)
Reference27 articles.
1. Dried blood spots for HIV-1 drug resistance and viral load testing: A review of current knowledge and WHO efforts for global HIV drug resistance surveillance.;S Bertagnolio;AIDS Rev.,2010
2. HIV-1 drug resistance genotyping success rates and correlates of Dried-blood spots and plasma specimen genotyping failure in a resource-limited setting.;J Omooja;BMC Infect Dis,2022
3. Measurement of HIV-1 viral load for drug resistance surveillance using dried blood spots: literature review and modeling of contribution of DNA and RNA;NT Parkin;AIDS Rev,2014
4. Diagnostic Accuracy of Dried Plasma Spot Specimens for HIV-1 Viral Load Testing: A Systematic Review and Meta-analysis;Y Fong;J Acquir Immune Defic Syndr.,2022
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献