Real-world performance of point-of-care vs. standard-of-care HIV viral load testing in western Kenya: Secondary analysis of Opt4Kids and Opt4Mamas studies

Author:

Giang Jessica H.ORCID,Basha Garoma,Thomas Katherine K.,Oyaro Patrick,Chohan Bhavna H.,Kingwara Leonard,Hassan Shukri A.,Yongo Nashon,Wagude James,Oluoch Fredrick,Odhiambo Francesca,Oyaro BoazORCID,John-Stewart Grace C.,Abuogi Lisa L.ORCID,Patel Rena C.ORCID

Abstract

Routine HIV viral load testing is important for evaluating HIV treatment outcomes, but conventional viral load testing has many barriers including expensive laboratory equipment and lengthy results return times to patients. A point-of-care viral load testing technology, such as GeneXpert HIV-1 quantification assay, could reduce these barriers by decreasing cost and turnaround time, however real-world performance is limited. We conducted a secondary analysis using 900 samples collected from participants in two studies to examine the performance of GeneXpert as point-of-care viral load compared to standard-of-care testing (which was conducted with two centralized laboratories using traditional HIV-1 RNA PCR quantification assays). The two studies, Opt4Kids (n = 704 participants) and Opt4Mamas (n = 820 participants), were conducted in western Kenya from 2019–2021 to evaluate the effectiveness of a combined intervention strategy, which included point-of-care viral load testing. Paired viral load results were compared using four different thresholds for virological non-suppression, namely ≥50, ≥200, ≥400, ≥1000 copies/ml. At a threshold of ≥1000 copies/mL, paired samples collected on the same day: demonstrated sensitivities of 90.0% (95% confidence interval [CI] 68.3, 98.8) and 66.7% (9.4, 99.2), specificities of 98.4% (95.5, 99.7) and 100% (96.5, 100), and percent agreements of 97.7% (94.6, 99.2) and 99.1% (95.0, 100) in Opt4Kids and Opt4Mamas studies, respectively. When lower viral load thresholds were used and the paired samples were collected an increasing number of days apart, sensitivity, specificity, and percent agreement generally decreased. While specificity and percent agreement were uniformly high, sensitivity was lower than expected. Non-specificity of the standard of care testing may have been responsible for the sensitivity values. Nonetheless, our results demonstrate that GeneXpert may be used reliably to monitor HIV treatment in low- and middle- income countries to attain UNAID’s 95-95-95 HIV goals.

Funder

National Institutes of Mental Health of the U.S. National Institutes of Health

Thrasher Research Fund

Publisher

Public Library of Science (PLoS)

Reference27 articles.

1. National AIDS and STI Control Programme (NASCOP). Preliminary KENPHIA 2018 Report Kenya Ministry of Health, Nairobi, Kenya.; 2020.

2. NASCOP. Ministry of Health, National AIDS & STI Control Program. Guidelines on Use of Antiretroviral Drugs for Treating and Preventing HIV Infection in Kenya 2018 Edition, Print.; 2018.

3. National AIDS & STI Control Programme (NASCOP). Kenya HIV Prevention and Treatment Guidelines.

4. Near Point-of-Care HIV Viral Load: Targeted Testing at Large Facilities;P Ganesh;J Acquir Immune Defic Syndr,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3