Sources of variation and establishment of Russian reference intervals for major hormones and tumor markers

Author:

Ruzhanskaya AnnaORCID,Ichihara Kiyoshi,Evgina Svetlana,Skibo Irina,Vybornova Nina,Vasiliev AntonORCID,Agarkova Galina,Emanuel Vladimir

Abstract

Objectives A multicenter study was organized to explore sources of variation (SVs) of reference values (RVs) for 22 major immunochemistry analytes and to determine reference intervals (RIs) for the Russian population. Methods According to IFCC Committee on Reference Intervals and Decision Limits (C-RIDL) protocol, 758 healthy volunteers were recruited in St. Petersburg, Moscow, and Yekaterinburg. Serum samples were tested for five tumor markers, 17 hormones and related tests by Beckman Coulter’s UniCel DxI 800 immunochemistry analyzer. SVs were explored using multiple regression analysis and ANOVA. Standard deviation ratio (SDR) of 0.4 was used as primary guide for partitioning RIs by gender and age. Results SDR for between-city difference was <0.4 for all analytes. Secondary exclusion of individuals was done under the following conditions: for female sex-hormones, those with contraceptives (8%); for CA19-9, those supposed to have negative Lewis blood-group (10.5% males and 11.3% females); for insulin, those with BMI≥28 kg/m2 (31%); for the thyroid panel, those with anti-thyroid antibodies (10.3% males; 24.5% females), for CEA those with smoking habit (30% males and 16% females). Gender-specific RIs were required for all analytes except CA19-9, CA15-3, thyroid-related tests, parathyroid hormone, and insulin. Age-specific RIs were required for alpha-fetoprotein, CEA, all sex-hormones for females, FSH and progesterone for both sexes. RIs were generally derived by parametric method after Gaussian transformation using modified Box-Cox formula. Exceptions were growth hormone, estradiol for females in postmenopause, and progesterone for females in premenopause, for which nonparametric method was required due to bimodal distribution and/or insufficient detection limit. Conclusion RIs for major hormones and tumor markers specific for the Russian population were derived based on the up-to-date internationally harmonized protocol by careful consideration of analyte-specific SVs.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference40 articles.

1. IFCC and CLSI. EP28-A3C Defining, establishing, and verifying reference intervals in the clinical laboratory; approved guideline, third edition. 2010; vol.28, No.30.

2. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values;Committee on Reference Intervals and Decision Limits (C-RIDL);Clin Chem Lab Med,2013

3. Establishing reference intervals for major biochemical analytes for the Russian population: a research conducted as a part of the IFCC global study on reference values;S Evgina;Clin Biochem,2020

4. The Asian project for collaborative derivation of reference intervals: (2) results of non-standardized analytes and transference of reference intervals to the participating laboratories on the basis of cross-comparison of test results;K Ichihara;Clin Chem Lab Med,2013

5. Establishment of reference intervals for immunoassay analytes of adult population in Saudi Arabia;A Borai;Clin Chem Lab Med,2020