Accuracy and reliability of self-administered visual acuity tests: Systematic review of pragmatic trials

Author:

Thirunavukarasu Arun JamesORCID,Hassan Refaat,Limonard Aaron,Savant Shalom VitreousORCID

Abstract

Background Remote self-administered visual acuity (VA) tests have the potential to allow patients and non-specialists to assess vision without eye health professional input. Validation in pragmatic trials is necessary to demonstrate the accuracy and reliability of tests in relevant settings to justify deployment. Here, published pragmatic trials of these tests were synthesised to summarise the effectiveness of available options and appraise the quality of their supporting evidence. Methods A systematic review was undertaken in accordance with a preregistered protocol (CRD42022385045). The Cochrane Library, Embase, MEDLINE, and Scopus were searched. Screening was conducted according to the following criteria: (1) English language; (2) primary research article; (3) visual acuity test conducted out of eye clinic; (4) no clinical administration of remote test; (5) accuracy or reliability of remote test analysed. There were no restrictions on trial participants. Quality assessment was conducted with QUADAS-2. Results Of 1227 identified reports, 10 studies were ultimately included. One study was at high risk of bias and two studies exhibited concerning features of bias; all studies were applicable. Three trials—of DigiVis, iSight Professional, and Peek Acuity—from two studies suggested that accuracy of the remote tests is comparable to clinical assessment. All other trials exhibited inferior accuracy, including conflicting results from a pooled study of iSight Professional and Peek Acuity. Two studies evaluated test-retest agreement—one trial provided evidence that DigiVis is as reliable as clinical assessment. The three most accurate tests required access to digital devices. Reporting was inconsistent and often incomplete, particularly with regards to describing methods and conducting statistical analysis. Conclusions Remote self-administered VA tests appear promising, but further pragmatic trials are indicated to justify deployment in carefully defined contexts to facilitate patient or non-specialist led assessment. Deployment could augment teleophthalmology, non-specialist eye assessment, pre-consultation triage, and autonomous long-term monitoring of vision.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference48 articles.

1. Models of care in tele-ophthalmology: A scoping review;L.J. Caffery;J Telemed Telecare,2019

2. Is your vision blurry?;A. Samanta;A systematic review of home-based visual acuity for telemedicine, J Telemed Telecare.,2020

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3