Development of an automatic device performing chest compression and external defibrillation: An animal-based pilot study

Author:

Roh Young-IlORCID,Jung Woo Jin,Im Hyeon Young,Lee Yujin,Im Dahye,Cha Kyoung-ChulORCID,Hwang Sung OhORCID

Abstract

Background Automatic chest compression devices (ACCDs) can promote high-quality cardiopulmonary resuscitation (CPR) and are widely used worldwide. Early application of automated external defibrillators (AEDs) along with high-quality CPR is crucial for favorable outcomes in patients with cardiac arrest. Here, we developed an automated CPR (A-CPR) apparatus that combines ACCD and AED and evaluated its performance in a pilot animal-based study. Methods Eleven pigs (n = 5, A-CPR group; n = 6, ACCD CPR and AED [conventional CPR (C-CPR)] group) were enrolled in this study. After 2 min observation without any treatment following ventricular fibrillation induction, CPR with a 30:2 compression/ventilation ratio was performed for 6 min, mimicking basic life support (BLS). A-CPR or C-CPR was applied immediately after BLS, and resuscitation including chest compression and defibrillation, was performed following a voice prompt from the A-CPR device or AED. Hemodynamic parameters, including aortic pressure, right atrial pressure, coronary perfusion pressure, carotid blood flow, and end-tidal carbon dioxide, were monitored during resuscitation. Time variables, including time to start rhythm analysis, time to charge, time to defibrillate, and time to subsequent chest compression, were also measured. Results There were no differences in baseline characteristics, except for arterial carbon dioxide pressure (39 in A-CPR vs. 33 in C-CPR, p = 0.034), between the two groups. There were no differences in hemodynamic parameters between the groups. However, time to charge (28.9 ± 5.6 s, A-CPR group; 47.2 ± 12.4 s, C-CPR group), time to defibrillate (29.1 ± 7.2 s, A-CPR group; 50.5 ± 12.3 s, C-CPR group), and time to subsequent chest compression (32.4 ± 6.3 s, A-CPR group; 56.3 ± 10.7 s, C-CPR group) were shorter in the A-CPR group than in the C-CPR group (p = 0.015, 0.034 and 0.02 respectively). Conclusions A-CPR can provide effective chest compressions and defibrillation, thereby shortening the time required for defibrillation.

Funder

Korea Medical Device Development Fund

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3