Differences in aortic valve area measured on cardiac CT and echocardiography in patients with aortic stenosis

Author:

Choe JooaeORCID,Koo Hyun JungORCID,Choi Se JinORCID,Lee Seung-Ah,Kim Dae-Hee,Song Jong-Min,Kang Duk-Hyun,Song Jae-Kwan,Kang Joon-Won,Yang Dong Hyun

Abstract

Background A certain proportion of patients with severe aortic stenosis (AS) present with discordant grading between different diagnostic modalities, which raises uncertainty about the true severity of AS. The aim of this study was to compare the aortic valve area (AVA) measured on CT and echocardiography and demonstrate the factors affecting AVA discrepancies. Methods Between June 2011 and March 2016, 535 consecutive patients (66.83±8.80 years, 297 men) with AS who underwent pre-operative cardiac CT and echocardiography for aortic valve replacement were retrospectively included. AVA was obtained by AVA on echocardiography (AVAecho) and CT (AVACT) using a measurement of the left ventricular outflow tract on each modality and correlations between those measures were evaluated. Logistic regression analysis was performed to identify factors affecting the discordance for grading severe AS. Results The AVACT and AVAecho showed a high correlation (r: 0.79, P <0.001) but AVACT was larger than the AVAecho (difference 0.26 cm2, P <0.001). By using the cut-off values of AVACT (<1.2 cm2) and AVAecho (<1.0 cm2) for diagnosing severe AS, the BSA (odds ratio [OR]: 68.03, 95% confidence interval [CI]: 5.45–849.99; P = 0.001), AVAecho (OR: 1.19, 95%CI: 1.14–1.24; P <0.001), tricuspid valve morphology (OR: 2.83, 95%CI: 1.23–6.50; P = 0.01), and normalized annulus area (OR: 1.02; 95%CI:1.02–1.03; P <0.001) were significant factors associated with the discordance between the AVAecho and AVACT. Conclusion Patients with larger BSA, AVAecho, and annulus, and tricuspid valve morphology were associated with the AVA discordance between the echocardiography and CT. Complementary use of CT with echocardiography for grading severe AS could be helpful in such conditions.

Funder

Korea government

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3