Capturing the attentional response to clinical auditory alarms: An ERP study on priority pulses

Author:

Ribeiro Ferreira VascoORCID,Pereira Ana Rita,Vieira Joana,Pereira Frederico,Marques Rui,Campos GuilhermeORCID,Sampaio Adriana,Crego AlbertoORCID

Abstract

Clinical auditory alarms are often found in hospital wards and operating rooms. In these environments, regular daily tasks can result in having a multitude of concurrent sounds (from staff and patients, building systems, carts, cleaning devices, and importantly, patient monitoring devices) which easily amount to a prevalent cacophony. The negative impact of this soundscape on staff and patients’ health and well-being, as well as in their performance, demand for accordingly designed sound alarms. The recently updated IEC60601-1-8 standard, in guidance for medical equipment auditory alarms, proposed a set of pointers to distinctly convey medium or high levels of priority (urgency). However, conveying priority without compromising other features, such as ease of learnability and detectability, is an ongoing challenge. Electroencephalography, a non-invasive technique for measuring the brain response to a given stimulus, suggests that certain Event-Related Potentials (ERPs) components such as the Mismatch Negativity (MMN) and P3a may be the key to uncovering how sounds are processed at the pre-attentional level and how they may capture our attention. In this study, the brain dynamics in response to the priority pulses of the updated IEC60601-1-8 standard was studied via ERPs (MMN and P3a), for a soundscape characterised by the repetition of a sound (generic SpO2 “beep”), usually present in operating and recovery rooms. Additional behavioural experiments assessed the behavioural response to these priority pulses. Results showed that the Medium Priority pulse elicits a larger MMN and P3a peak amplitude when compared to the High Priority pulse. This suggests that, at least for the applied soundscape, the Medium Priority pulse is more easily detected and attended at the neural level. Behavioural data supports this indication, showing significantly shorter reaction times for the Medium Priority pulse. The results pose the possibility that priority pointers of the updated IEC60601-1-8 standard may not be successfully conveying their intended priority levels, which may not only be due to design properties but also to the soundscape in which these clinical alarms are deployed. This study highlights the need for intervention in both hospital soundscapes and auditory alarm design settings.

Funder

Foundation for Science and Technology

FCT and the European Regional Development Fund

FCT and the Portuguese Ministry of Science, Technology and Higher Education

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference44 articles.

1. A Review of Design Guidelines for Clinical Auditory Alarms

2. Are Melodic Medical Equipment Alarms Easily Learned?;AN Wee;Anesth Analg,2008

3. Overlapping Melodic Alarms Are Almost Indiscriminable;P Lacherez;Hum Factors J Hum Factors Ergon Soc,2007

4. ECRI Institute. Top 10 Technology Hazards for 2012. 2012; www.ecri.org

5. ECRI Institute. Top 10 Health Technology Hazards for 2018, (November 2016). 2018; www.ecri.org

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3