Reliability of surface electromyographic (sEMG) measures of equine axial and appendicular muscles during overground trot

Author:

St. George L.ORCID,Spoormakers T. J. P.ORCID,Roy S. H.,Hobbs S. J.ORCID,Clayton H. M.,Richards J.,Serra Bragança F. M.

Abstract

The reliability of surface electromyography (sEMG) has not been adequately demonstrated in the equine literature and is an essential consideration as a methodology for application in clinical gait analysis. This observational study investigated within-session, intra-subject (stride-to-stride) and inter-subject reliability, and between-session reliability of normalised sEMG activity profiles, from triceps brachii (triceps), latissimus dorsi (latissimus), longissimus dorsi (longissimus), biceps femoris (biceps), superficial gluteal (gluteal) and semitendinosus muscles in n = 8 clinically non-lame horses during in-hand trot. sEMG sensors were bilaterally located on muscles to collect data during two test sessions (session 1 and 2) with a minimum 24-hour interval. Raw sEMG signals from ten trot strides per horse and session were DC-offset removed, high-pass filtered (40 Hz), full-wave rectified, and low-pass filtered (25 Hz). Signals were normalised to peak amplitude and percent stride before calculating intra- and inter-subject ensemble average sEMG profiles across strides for each muscle and session. sEMG profiles were assessed using waveform similarity statistics: the coefficient of variation (CV) to assess intra- and inter-subject reliability and the adjusted coefficient of multiple correlation (CMC) to evaluate between-session reliability. Across muscles, CV data revealed that intra-horse sEMG profiles within- and between-sessions were comparatively more reliable than inter-horse profiles. Bilateral gluteal, semitendinosus, triceps and longissimus (at T14 and L1) and right biceps showed excellent between-session reliability with group-averaged CMCs > 0.90 (range 0.90–0.97). Bilateral latissimus and left biceps showed good between-session reliability with group-averaged CMCs > 0.75 (range 0.78–0.88). sEMG profiles can reliably describe fundamental muscle activity patterns for selected equine muscles within a test session for individual horses (intra-subject). However, these profiles are more variable across horses (inter-subject) and between sessions (between-session reliability), suggesting that it is reasonable to use sEMG to objectively monitor the intra-individual activity of these muscles across multiple gait evaluation sessions at in-hand trot.

Funder

Morris Animal Foundation

British Society of Animal Science

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3