Assessment of 18F-DCFPyL PSMA PET/CT and PET/MR quantitative parameters for reference standard organs: Inter-reader, inter-modality, and inter-patient variability

Author:

Lawrence Edward M.ORCID,Kieler Minnie,Cooley Greg,Wells Shane A.,Cho Steve Y.

Abstract

Prostate specific membrane antigen (PSMA)-based radiotracers have shown promise for prostate cancer assessment. Evaluation of quantitative variability and establishment of reference standards are important for optimal clinical and research utility. This work evaluates the variability of PSMA-based [18F]DCFPyL (PyL) PET quantitative reference standards. Consecutive eligible patients with biochemically recurrent prostate cancer were recruited for study participation from August 2016-October 2017. After PyL tracer injection, whole body PET/CT (wbPET/CT) was obtained with subsequent whole body PET/MR (wbPET/MR). Two readers independently created regions of interest (ROIs) including a 40% standardized uptake value (SUV) threshold ROI of the whole right parotid gland and separate spherical ROIs in the superior, mid, and inferior gland. Additional liver (right lobe) and blood pool spherical ROIs were defined. Bland-Altman analysis, including limits of agreement (LOA), as well as interquartile range (IQR) and coefficient of variance (CoV) was used. Twelve patients with prostate cancer were recruited (mean age, 61.8 yrs; range 54–72 years). One patient did not have wbPET/MR and was excluded. There was minimal inter-reader SUVmean variability (bias±LOA) for blood pool (-0.13±0.42; 0.01±0.41), liver (-0.55±0.82; -0.22±1.3), or whole parotid gland (-0.05±0.31; 0.08±0.24) for wbPET/CT and wbPET/MR, respectively. Greater inter-reader variability for the 1-cm parotid gland ROIs was present, for both wbPET/CT and wbPET/MR. Comparing wbPET/CT to the subsequently acquired wbPET/MR, blood pool had a slight decrease in SUVmean. The liver as well as parotid gland showed a slight increase in activity although the absolute bias only ranged from 0.45–1.28. The magnitude of inter-subject variability was higher for the parotid gland regardless of modality or reader. In conclusion, liver, blood pool, and whole parotid gland quantitation show promise as reliable reference normal organs for clinical/research PET applications. Variability with 1-cm parotid ROIs may limit its use.

Funder

School of Medicine and Public Health, University of Wisconsin-Madison

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3