Diagnostic accuracy of Xpert MTB/RIF Ultra and culture assays to detect Mycobacterium Tuberculosis using OMNIgene-sputum processed stool among adult TB presumptive patients in Uganda

Author:

Sessolo AbdulwahabORCID,Musisi Emmanuel,Kaswabuli Sylvia,Zawedde Josephine,Byanyima Patrick,Sabiiti WilberORCID,Walimbwa Stanley,Ola Joseph,Sanyu Ingvar,Lalitha RejaniORCID,Kamya Moses,Davis LucianORCID,Worodria William,Huang Laurence

Abstract

Background Stool is a potential sample for diagnosing Mycobacterium tuberculosis (Mtb) in patients with difficulty in expectorating. However, high mycobacterial culture contamination rates and Xpert MTB/RIF Ultra test error rates on stool samples have limited its use. OMNIgene SPUTUM (OM-S) is a sample transport reagent with characteristics of sputum decontamination while maintaining viable Mtb. We evaluated the impact of OM-S on Mtb diagnostic yield from stool using smear microscopy, Xpert MTB/RIF Ultra, and culture among presumptive TB patients. Methods Paired stool and expectorated sputum samples were collected from consecutive Ugandan adults undergoing diagnostic evaluation for pulmonary TB between June 2018 and June 2019. Stool was divided into 2 portions: one was homogenized in OM-S (OM-S stool) and the other in PBS (PBS stool) as control. Both sputum and processed stool were tested for Mtb using concentrated smear fluorescence microscopy (CFM), Xpert MTB/RIF Ultra (Xpert) and Mycobacteria Growth Indicator Tube (MGIT) culture. Sensitivity, specificity, and predictive values for each test were calculated against sputum MGIT culture as the reference standard. Results Of the 200 participants, 120 (60%) were male, 73 (37%) were HIV positive (median CD4 120 cells/uL (IQR 43–297)) and 128 (64%) had confirmed pulmonary TB by sputum MGIT culture. Seven (4%) OM-S stool Xpert samples reported errors while 47 (25%) and 103 (61%) were contaminated on OM-S stool MGIT and PBS stool MGIT, respectively. OM-S stool MGIT was able to accurately diagnose 56 of the contaminated PBS stool MGIT samples compared to only 5 of the contaminated OM-S stool MGIT samples diagnosed by PBS stool MGIT. Sensitivity (95% Confidence Interval, CI) 89% (83–94) for OM-S stool Xpert was higher compared to that of OM-S stool MGIT 60% (51–69) and PBS stool MGIT 42% (32–52). Specificity (95%CI) 91% (82–97) was also higher for OM-S stool Xpert compared to OM-S stool MGIT 64% (51–75) and PBS stool MGIT 26% (16–38). Conclusion Stool processed with OM-S showed potential to improve Mtb diagnostic yield and reduce rates of indeterminate results when tested on Xpert and MGIT culture. The method may thus be of value in Mtb detection among patients with difficulty to expectorate.

Funder

Academy for Health Innovation Uganda

National Heart, Lung, and Blood Institute

DNAgenotek Inc.

SPUTUM

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference35 articles.

1. ‘Suspected pulmonary tuberculosis in rural South Africa-Sputum induction as a simple diagnostic tool?;T Hartung;South African Medical Journal,2002

2. ‘Assessment of the Xpert MTB/RIF assay for diagnosis of tuberculosis with gastric lavage aspirates in children in sub-Saharan Africa: a prospective descriptive study;O Bates M;The Lancet infectious diseases,2013

3. ‘Childhood pulmonary tuberculosis: old wisdom and new challenges;BJ Marais;American journal of respiratory and critical care medicine,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3