Comparison between passive knee kinematics during surgery and active knee kinematics during walking: A preliminary study

Author:

Gasparutto XavierORCID,Bonnefoy-Mazure Alice,Attias Michael,Dumas RaphaëlORCID,Armand Stéphane,Miozzari Hermès

Abstract

Recovery of function is among a patient’s main expectations when undergoing total knee arthroplasty (TKA). However, normal gait knee function is not always completely restored, which can affect patient satisfaction and quality of life. Computer-assisted surgery (CAS) allows surgeons to evaluate passive knee kinematics intra-operatively. Understanding associations between knee kinematics measured during surgery and during daily activities, such as walking, could help define criteria for success based on knee function and not only on the correct alignment of the implant or the leg. This preliminary study compared passive knee kinematics measured during surgery with active kinematics measured during walking. Eight patients underwent a treadmill gait analysis using the KneeKG™ system both before surgery and three months afterwards. Knee kinematics were measured during CAS both before and after TKA implantation. The anatomical axes of the KneeKG™ and CAS systems were homogenised using a two-level, multi-body kinematics optimisation with a kinematic chain based on the calibration measured during CAS. A Bland–Altman analysis was performed before and after TKA for adduction–abduction angle, internal–external rotation, and anterior–posterior displacement over the whole gait cycle, at the single stance phase and at the swing phase. Homogenising the anatomical axes between CAS and treadmill gait led to limited median bias and limits of agreement (post-surgery -0.6 ± 3.6 deg, -2.7 ± 3.6 deg, and -0.2 ± 2.4 mm for adduction–abduction, internal–external rotation and anterior–posterior displacement, respectively). At the individual level, correlations between the two systems were mostly weak (R2 < 0.3) over the whole gait cycle, indicating low kinematic consistency between the two measurements. However, correlations were better at the phase level, especially the swing phase. The multiple sources of differences did not enable us to conclude whether they came from anatomical and biomechanical differences or from measurement system errors.

Funder

Department of Orthopaedic Surgery, Boston University School of Medicine

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3