Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography

Author:

Chang Chia-Hao,Wu Hsiang-Ning,Hsu Ching-HanORCID,Lin Hsin-HonORCID

Abstract

Metal artifacts present a major challenge to computed tomography (CT) because they reduce the image quality in medical diagnosis and treatment. Several metal artifact reduction (MAR) methods have been proposed to address this issue in previous studies. This study aimed to synthesize a virtual monochromatic image for MAR in CT images using projection-based material decomposition (MD) algorithms. We developed a spectral micro-CT prototype system equipped with a photon-counting detector (PCD) and PCD-CT imaging simulator to assess the performances of different MAR methods. Two projection-based MD algorithms were implemented and evaluated for their MAR performances in CT images and compared with conventional sinogram inpainting MAR methods. Different parts of digital 4D-extended cardiac torso (XCAT) phantoms with metal implants were designed to simulate various real scenarios. A homemade metal artifact evaluation (MAE) phantom was used to evaluate the MAR performance in experiments. The simulated results of the XCAT phantom indicated that the projection-based virtual monochromatic CT (VMCT) images provided better image quality than the conventional MAR images without blurring the normal tissues at the position of the metal artifacts. Various quantitative indicators support this conclusion. Additionally, the experimental results of the MAE phantom reveal that projection-based VMCT images can avoid image distortion caused by metal artifacts, unlike conventional MAR methods. In regards to the projection-based VMCT images, the simulated and experimental results demonstrated that using the linear maximum likelihood estimators with an error correction look-up table algorithm yielded better MAR performance compared to that obtained using a polynomial algorithm. Furthermore, projection-based VMCT images can not only reduce metal artifacts effectively but also simultaneously prevents object blurring at the metal artifact position and image distortion of the metal implants. Hence, the CT image quality can be further improved to increase the abilities for both preoperative and postoperative assessment of metal implants.

Funder

Chang Gung Memorial Hospital

National Science and Technology Council

Atomic Energy Council of Taiwan

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference46 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3