Transcoronary electrophysiological parameters in patients undergoing elective and acute coronary intervention

Author:

Javid Rabeia,Slater Thomas A.,Bowes Robert,Veerasamy Murugapathy,Wassef Nancy,Rossington Jennifer A.ORCID,Mozid Abdul M.,Kidambi Ananth,Wheatcroft Stephen B.,Tayebjee Muzahir H.ORCID

Abstract

Introduction Percutaneous coronary intervention is performed routinely in the management of myocardial infarction with obstructive coronary disease, but intervention to arteries supplying nonviable myocardium may be harmful. It is important therefore to establish myocardial viability, and there is an unmet need in current clinical practice for real time viability assessment to aid in decision making. Transcoronary pacing to assess myocardial electrophysiological parameters may be a novel viability assessment technique which could be used in this regard. Methods Coronary intervention was carried out according to standard departmental procedure with standard equipment. An exchange length coronary guidewire was passed into both target and reference coronary vessels and an over-the-wire balloon or microcatheter was used to insulate the guidewire and allow electrophysiological parameters to be assessed. Readings were obtained from all major epicardial vessels and substantial branches. At each position, an intracoronary electrocardiogram was recorded, and R wave amplitude was measured. Transcoronary pacing was then performed to establish threshold and impedance for each myocardial segment. A viability cardiac MRI scan was performed for each patient. A standard segmental model was used to determine viability in each segment using an ‘infarct score’ based on degree of late gadolinium enhancement. Studies were reported blinded to the electrical parameters obtained from the coronary guidewire. The primary outcome was the relationship between pacing threshold and myocardial segment infarct score. Secondary outcomes included the relationship between segmental infarct score and R wave height, and between segmental infarct score and pacing impedance. Data were collected on the feasibility of studying the coronary segments as well as safety. Results Sixty-five patients presenting with stable coronary artery disease or acute coronary syndromes to Leeds General Infirmary between September 2019 and August 2021 were included in the study. Electrophysiological parameters from segments with an infarct score of zero were obtained, with wide variances seen, with no significant difference in impedance or threshold in any territory. There was a significant difference in sensitivity for segments in the right coronary artery territory for both elective and acute patients. This likely relates to reduced myocardial mass in these territories. No significant association between infarct score and sensitivity, impedance or threshold were seen. Conclusion This study has established intracoronary electrophysiological parameters in both normal myocardium and areas of myocardial scar. No reliable association was seen between impedance, threshold or R wave amplitude and degree of myocardial viability, contrasting with prior findings from our group and others. More work is therefore required to fully understand the role of transcoronary pacing in this setting.

Funder

Abbott Laboratories

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference15 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3