Diagnostic performance of anti-Zika virus IgM, IgAM and IgG ELISAs during co-circulation of Zika, dengue, and chikungunya viruses in Brazil and Venezuela
-
Published:2021-04-19
Issue:4
Volume:15
Page:e0009336
-
ISSN:1935-2735
-
Container-title:PLOS Neglected Tropical Diseases
-
language:en
-
Short-container-title:PLoS Negl Trop Dis
Author:
Morales IvonneORCID, Rosenberger Kerstin D.ORCID, Magalhaes Tereza, Morais Clarice N. L.ORCID, Braga CynthiaORCID, Marques Ernesto T. A.ORCID, Calvet Guilherme AmaralORCID, Damasceno LuanaORCID, Brasil Patricia, Bispo de Filippis Ana MariaORCID, Tami AdrianaORCID, Bethencourt Sarah, Alvarez Mayling, Martínez Pedro A.ORCID, Guzman Maria G., Souza Benevides BrunoORCID, Caprara AndreaORCID, Quyen Nguyen Than HaORCID, Simmons Cameron P.ORCID, Wills BridgetORCID, de Lamballerie Xavier, Drexler Jan Felix, Jaenisch ThomasORCID,
Abstract
Background
Serological diagnosis of Zika virus (ZIKV) infection is challenging because of the antibody cross-reactivity among flaviviruses. At the same time, the role of Nucleic Acid Testing (NAT) is limited by the low proportion of symptomatic infections and the low average viral load. Here, we compared the diagnostic performance of commercially available IgM, IgAM, and IgG ELISAs in sequential samples during the ZIKV and chikungunya (CHIKV) epidemics and co-circulation of dengue virus (DENV) in Brazil and Venezuela.
Methodology/Principal findings
Acute (day of illness 1–5) and follow-up (day of illness ≥ 6) blood samples were collected from nine hundred and seven symptomatic patients enrolled in a prospective multicenter study between June 2012 and August 2016. Acute samples were tested by RT-PCR for ZIKV, DENV, and CHIKV. Acute and follow-up samples were tested for IgM, IgAM, and IgG antibodies to ZIKV using commercially available ELISAs. Among follow-up samples with a RT-PCR confirmed ZIKV infection, anti-ZIKV IgAM sensitivity was 93.5% (43/46), while IgM and IgG exhibited sensitivities of 30.3% (10/33) and 72% (18/25), respectively. An additional 24% (26/109) of ZIKV infections were detected via IgAM seroconversion in ZIKV/DENV/CHIKV RT-PCR negative patients. The specificity of anti-ZIKV IgM was estimated at 93% and that of IgAM at 85%.
Conclusions/Significance
Our findings exemplify the challenges of the assessment of test performance for ZIKV serological tests in the real-world setting, during co-circulation of DENV, ZIKV, and CHIKV. However, we can also demonstrate that the IgAM immunoassay exhibits superior sensitivity to detect ZIKV RT-PCR confirmed infections compared to IgG and IgM immunoassays. The IgAM assay also proves to be promising for detection of anti-ZIKV seroconversions in sequential samples, both in ZIKV PCR-positive as well as PCR-negative patients, making this a candidate assay for serological monitoring of pregnant women in future ZIKV outbreaks.
Funder
Seventh Framework Programme European Union’s Horizon 2020 research and innovation program Faperj Brazilian Ministry of Health
Publisher
Public Library of Science (PLoS)
Subject
Infectious Diseases,Public Health, Environmental and Occupational Health
Reference68 articles.
1. Zika virus. I. Isolations and serological specificity;GW Dick;Trans R Soc Trop Med Hyg,1952 2. Re-visiting the evolution, dispersal and epidemiology of Zika virus in Asia;JH Pettersson;Emerg Microbes Infect,2018 3. Zika virus outbreak on Yap Island, Federated States of Micronesia;MR Duffy;N Engl J Med,2009 4. Zika virus, French polynesia, South pacific, 2013;VM Cao-Lormeau;Emerg Infect Dis,2014 5. Co-infection with Zika and dengue viruses in 2 patients, New Caledonia, 2014;M Dupont-Rouzeyrol;Emerg Infect Dis,2015
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|