Author:
Abdu-Alfattah Mohanned A.,Othman Tahseen T.,Ahmed Omer K.
Abstract
The last stage endured on obvious erosion especially the front and the end of the blade. The erosion caused the appearance some cracks in this place. These remarks coincided with the theoretic al results, which were acquired according to the condition of the turbine of station which showed that the droplet, which collided with the blade ends, caused high pressure on the surface of the blade and caused the occurrence of the corrosion. The danger of the erosion unavoidable due to its relationship with tae station efficiency and the only to avoid that is the use of the blade made of erosion resistance ingots.
Reference6 articles.
1. Moore,.M.J, Sievrding .C.H, “Two Phase Steam Flow in Turbine and separator”, Mc-Graw Hill,1976..
2. Krzyzanowski and et al,”Semi- Empirical of Erosion Threat in Modern Steam Turbine”,ASME Journal of Power for Engineering,Vol 93,No 1,1971.
3. Krzyzanowski, “The Correlation Between Droplet Stream Structure and Steam Turbine Blading Erosion” ,ASME Journal of Power for Engineering,Vol 96,No 4,1974.
4. Krzyzanowski and Szperie, “The Influence of Droplet Size On The turbine Blading Erosion Hazard”, ASME Journal of Power for Engineering, Vol 100,No 4,1978.
5. Yeoh ,C. C, and Young, J. B., “Non Equilibrium Through Flow Analysis of Low-Pressure Wet Steam Turbine”, ASME Journal of Power for Engineering, Vol 106, October 1989.