Affiliation:
1. Egypt – Japan University of Science and Technology (E-Just), School of Energy Resources and Environmental Engineering, New Borg El Arab City, Alexandria, Egypt
2. Water Pollution Research Department, National Research Center, Dokki, Cairo, Egypt
Abstract
Treatment of agricultural drainage water (ADW) in a down-flow hanging sponge (DHS) reactor has been investigated for a period of 1 y. The reactor was operated at different hydraulic retention times (HRTs) of 5.26, 2.63, and 1.5 h and corresponding organic loading rates (OLRs) of 2.01, 1.86, and 4.43 kg COD/m3 d, respectively. The results obtained indicated that, decreasing the HRT from 5.26 to 1.5 h negatively affected the chemical oxygen demand (COD) removal. Average COD percentage removal values dropped from 89.3 ± 5.4 to 72.2 ± 16% respectively. Total suspended solids (TSS) concentrations were reduced by 85.5 ± 8.3, 90.4 ± 2.1, and 91.4 ± 4.9 at HRTs of 5.26, 2.63, and 1.5 h, respectively. However, the nitrification efficiency was slightly decreased from 85.2 ± 17.4 to 82 ± 11.4% by decreasing the HRT from 5.26 to 1.5 h and increasing the OLR from 2.01 to 4.43 kg COD/m3 d, respectively. Likewise, reducing the HRT from 5.26 to 1.5 h exerted a slight negative effect on the removal of the total phosphorus (TP). Based on these results it is recommended to operate such a system at a HRT of 2.63 h and OLR not exceeding 2.0 kg COD/m3 d for providing an effluent quality complying with the standards regulating the use of treated wastewater for agricultural purposes.
Subject
Water Science and Technology
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献