Author:
Canziani R.,Vismara R.,Basilico D.,Zinni L.
Abstract
The paper reports the findings of four years of pilot-scale research on nitrogen removal in fixed-bed biofilters fed on real raw municipal wastewater. The plant was made of two fixed-bed biofilm reactors in series with an intermediate settling tank from which excess biomass from the first stage was discharged. The first filter was used for carbon removal either with oxygen or nitrates. The second filter was used for nitrification. The average nitrification rate at 20°C was 0.84 gNH4+-N m−2d−1 with 5 mg l−1 dissolved oxygen in the bulk liquid. Temperature dependence was calculated (rn = rn,20° 1,05T-20). The influent organic load strongly affected ammonia oxidation. If the organic loading exceeded 2.5 gCOD m−2 d−1 nitrification rate was reduced by 50%. Denitrification was performed by recycling nitrates back from the second filter and by using sewage itself as carbon source. Denitrification rate showed to be strongly dependent on temperature (rd = rd,20° 1.11T-20) and on the recycle rate. Hydrolysis of the colloidal COD fraction showed a similar dependence on both temperature and recycle rate. Therefore, it has been concluded that the hydrolysis of finely dispersed COD particles can be the limiting step of denitrification in the biofilter when real sewage is used as carbon source.
Subject
Water Science and Technology,Environmental Engineering
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献