Study on treatment of wastewater with low concentration of ammonia-nitrogen by vacuum plate membrane distillation technology

Author:

Wang Yao1,Li Tianxiang1,Zhu Jing1ORCID

Affiliation:

1. School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025, China

Abstract

Abstract The removal of low concentration ammonia-nitrogen in industrial wastewater is necessary before discharged into the environment. In this study, vacuum plate membrane distillation (VPMD) technology was utilized and operating parameters such as pH, feed temperature, vacuum degree, feed flow and time were investigated. Based on the experimental data, the heat and mass transfer mechanism and mathematic model were studied. The experimental results show that low solution pH was significantly beneficial to ammonia-nitrogen removal but permeate flux was nearly changeless. At pH = 4, a removal rate up to 93.33% was achieved. Ammonia-nitrogen mainly exists with NH4+ ions in acidic solution, so only water molecules pass through the membrane to acquire the water product in the permeate side. Increasing the temperature of the solution was disadvantageous to the ammonia-nitrogen removal due to membrane pores expanding and the mass transfer coefficient of NH3 molecules increasing; therefore a low temperature was chosen if possible. Because vapor pressure of the feed solution increases exponentially with temperature and results in membrane surface pressure difference increases, therefore increasing the temperature enhances the permeate flux. Raising the vacuum degree enhanced ammonia removal rate and permeate flux obviously, a vacuum degree of 0.09 MPa was chosen for the experiment. The effect of feed flow rate on ammonia-nitrogen removal instead of permeate flux is weak, the reason is that the boundary layer wears thin when the feed flow rate is increased, which is conducive to permeate flux increasing. In a two-parameter model of Knudsen diffusion, Poiseuille flow was chosen to demonstrate the heat and mass transfers in the process of VPMD in the study. Based on the experimental values of permeate flux, two parameters CK and CP in the model were calculated using a nonlinear fitting method software, which indicated that the Knudsen diffusion model more than the Poiseuille flow model was suitable. The maximum values of the relative average deviation (RAD) and root mean square difference (RMSD) of experimental and calculated values with model equations of the permeate flux at the different temperature, vacuum degree and feed flow rate were no more than 8.7% and 3.20 kg · (m2 · h)−1, respectively.

Funder

Open Foundation of State Key Laboratory of Efficient Utilization of Medium and Low Grade Phosphate Ore and Its Associated Resources

National Natural Science Foundation of China

Publisher

IWA Publishing

Subject

Water Science and Technology,Environmental Engineering

Reference37 articles.

1. Concentration of sucrose solutions via vacuum membrane distillation;Desalination,2006

2. Membrane distillation: a comprehensive review;Desalination,2012

3. Ammonia removal from aqueous solutions using hollow-fiber membrane contactors;Chem. Eng. J.,2010

4. Discussion and prospect of ammonia-nitrogen wastewater treatment technology;Chem. Manage.,2020

5. Heat and mass transfer in membrane distillation;J. Membr. Sci.,1987

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3